tag:blogger.com,1999:blog-32733256227885752092024-03-05T09:48:51.847-08:00ACONDICIONAMIENTO TERMICO EN LA ARQUITECTURAARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.comBlogger35125tag:blogger.com,1999:blog-3273325622788575209.post-42312729874466698432014-09-05T08:27:00.003-07:002014-09-05T08:27:20.052-07:00<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg4OKGTmfZL_k_BfNytn2SL92PUNFE28mgAW8J16HAtZhya5xosQv9tZz7cJL4ms-htCZVJVD88qhTyCxLADU-EmjDxOZ4Z6GBM2kCLukf77OHaMGU-WFGREpgHCCSLkH5fBIREd-Qbs5c/s1600/tarjetas_originalimprenta_02.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg4OKGTmfZL_k_BfNytn2SL92PUNFE28mgAW8J16HAtZhya5xosQv9tZz7cJL4ms-htCZVJVD88qhTyCxLADU-EmjDxOZ4Z6GBM2kCLukf77OHaMGU-WFGREpgHCCSLkH5fBIREd-Qbs5c/s1600/tarjetas_originalimprenta_02.png" height="204" width="320" /></a></div>
<br />
<span style="float: left;"><span style="font-family: Arial, Helvetica, sans-serif;">Tel: (03543) 15-553112 Cordoba / (011) 15-5496-1322 Buenos Aires</span></span><br />
<span style="font-family: Arial, Helvetica, sans-serif;"> mail: <a href="mailto:info@nativoarq.com.ar">info@nativoarq.com.ar</a> / diazfernandoariel@yahoo.com.ar </span><br />
<span style="font-family: Arial, Helvetica, sans-serif;">SITIO WEB: http://www.nativoARQ.com.ar </span><br />
<br />
REALIZAMOS PROYECTOS Y OBRAS, SU CONSULTA NO MOLESTA!ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-66818420452814788462013-02-16T04:43:00.000-08:002013-02-16T04:44:13.234-08:00APUNTES DE INSTALACIONES III, CATEDRA FAMA, 2013<br />
<h1>
<span style="font-size: small;">APUNTES DE INSTALACIONES III, CATEDRA FAMA, 2013</span></h1>
<div class="MsoNormal">
Por: ARQ. FERNANDO ARIEL DIAZ</div>
<div class="MsoNormal">
Este apunte ha sido realizado con el fin de distribuir los
conocimientos adquiridos luego de la cursada con ayuda de la lectura
exhaustiva del libro “INSTALACIONES DE
AIRE ACONDICIONADO Y CALEFACCIÓN del Ing. Néstor P. Quadri, con los apuntes
tomados en clase, con conceptos y gráficos suministrados por la cátedra FAMA de
la Facultad de Arquitectura Diseño y Urbanismo, U.B.A. y con mi experiencia en
el tema. <b><span style="font-size: large;">Espero les sea de ayuda.</span></b> </div>
<div class="MsoNormal">
<b><br /></b></div>
<div class="MsoNormal">
MÁS INFORMACION, DE ESTA, Y OTRAS MATERIAS EN: </div>
<div class="MsoNormal">
<span class="MsoHyperlink"><span style="font-family: "Verdana","sans-serif";">http://construccionesdh.blogspot.com.ar/ <o:p></o:p></span></span></div>
<div class="MsoNormal">
<a href="http://direccionylegislaciondeobra.blogspot.com.ar/"><span style="font-family: "Verdana","sans-serif";">http://direccionylegislaciondeobra.blogspot.com.ar/</span></a><span class="MsoHyperlink"><span style="font-family: "Verdana","sans-serif";"><o:p></o:p></span></span></div>
<div class="MsoNormal">
<a href="http://estructurasdehormigonarmado.blogspot.com.ar/"><span style="font-family: "Verdana","sans-serif";">http://estructurasdehormigonarmado.blogspot.com.ar/</span></a></div>
<div class="MsoNormal">
<span class="MsoHyperlink"><span style="font-family: "Verdana","sans-serif";">http://renacimiento--humanismo.blogspot.com.ar/<o:p></o:p></span></span></div>
<div class="MsoNormal">
<span class="MsoHyperlink"><span style="font-family: "Verdana","sans-serif";"><br /></span></span></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgoaCfAXjuqrnQ2G0bcCyaYVBT-i8drm3B66bSAUBNKkPJ3SVYtBNICzZ5JedjfBHFbOguMvc9CTIFlfVDTbKxBEJFJ_fC1y_xr3fMFcUOSrfHhMDvplkoujrwjR2-MIZTjHEvC9u4YyF0/s1600/FRENTE-TODAS-REFERENCIA.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgoaCfAXjuqrnQ2G0bcCyaYVBT-i8drm3B66bSAUBNKkPJ3SVYtBNICzZ5JedjfBHFbOguMvc9CTIFlfVDTbKxBEJFJ_fC1y_xr3fMFcUOSrfHhMDvplkoujrwjR2-MIZTjHEvC9u4YyF0/s1600/FRENTE-TODAS-REFERENCIA.jpg" height="320" width="177" /></a></div>
<div class="MsoNormal">
<span class="MsoHyperlink"><span style="font-family: "Verdana","sans-serif";"><br /></span></span></div>
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-26792675990576861242013-02-16T04:39:00.002-08:002013-02-16T04:39:41.508-08:00ACONDICIONAMIENTO TÉRMICO EN LA ARQUITECTURA<br />
<div style="border-bottom: solid #4F81BD 1.0pt; border: none; mso-border-bottom-themecolor: accent1; mso-element: para-border-div; padding: 0cm 0cm 4.0pt 0cm;">
<div class="MsoTitle">
Se puede definir como “la realización de funciones
destinadas a proporcionar durante todo el año una atmosfera interior saludable
y confortable, sin ruidos molestos y con el más bajo consumo energético
posible”. Estas funciones básicas son:</div>
</div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l2 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Refrigeración</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Calefacción</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Humectación</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Deshumectación</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Ventilación</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Filtrado</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l2 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Circulación.</div>
<div class="MsoNormal">
La refrigeración esta combinada con la Deshumectación en
verano, mientras que la calefacción está relacionada con la humectación en
invierno para zonas climáticas secas. La ventilación y el filtrado son
necesarios todo el año.</div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
Todo Equipo de Aire Acondicionado (A°A°) se compone de dos
partes:</div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l1 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Planta térmica y frigorífica</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l1 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Unidad de tratamiento del aire.</div>
<div class="MsoNormal">
Cuando estas partes están unificadas se lo denomina equipos
compactos autocontenidos. Cuando están separadas se las denomina a cada una
unidades terminales. </div>
<div class="MsoNormal">
<b> VENTILACION<o:p></o:p></b></div>
<div class="MsoNormal">
Es el aire que ingresa desde el exterior a través de una
reja de toma de aire y un conducto que lo conduce hacia un recinto llamado
pleno de mezcla, en él se mezcla con el aire de retorno proveniente del
interior del local. Consiste en suministrar aire nuevo lo más puro y limpio
posible a la interior evitando que se produzcan vaciamientos y acumulen olores,
diluyendo así estos contaminantes. Esta toma de aire debe ubicarse lejos de
sectores externos contaminantes como ser cocinas, baños, garajes, calles de
alto transito y en lo posible a 1 m. del piso evitando el mayor ingreso de
partículas de polvo. </div>
<div class="MsoNormal">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh6fOUa2O79zqKfSnS2JsbN54yKJrMrIFQWVyFJWhd0y6lryrAzm3kSt7XRwE8EimWKnHAPcdcD1OCk4zF2bqnZn4ynrmxXiGYFZogaw4Rhuz5XR8yKa312n613wgiFldzvnXF1nXRXjLo/s1600/puntos+de+analisis.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh6fOUa2O79zqKfSnS2JsbN54yKJrMrIFQWVyFJWhd0y6lryrAzm3kSt7XRwE8EimWKnHAPcdcD1OCk4zF2bqnZn4ynrmxXiGYFZogaw4Rhuz5XR8yKa312n613wgiFldzvnXF1nXRXjLo/s1600/puntos+de+analisis.JPG" height="227" width="320" /></a></div>
<div class="MsoNormal">
<br /><!--[endif]--></div>
<div class="MsoNormal">
Este aire que se incorpora crea una sobrepresión,
eliminándose por exfiltración a través de los cerramientos y aberturas del
interior al exterior, este efecto reduce el ingreso de aire y polvo exterior no
acondicionado.</div>
<div class="MsoNormal">
<b>FILTRADO<o:p></o:p></b></div>
<div class="MsoNormal">
Luego el aire mezclado pasa por una serie de filtros que le
quitan el polvo, impurezas y partículas en suspensión. Pueden ser:</div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 32.2pt; mso-add-space: auto; mso-list: l0 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->De superficie plana</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 68.2pt; mso-add-space: auto; mso-list: l0 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Metálicos, </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 68.2pt; mso-add-space: auto; mso-list: l0 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->De fibra, </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 68.2pt; mso-add-space: auto; mso-list: l0 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->De poliuretano, </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 32.2pt; mso-add-space: auto; mso-list: l0 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->De superficie expandida</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 68.2pt; mso-add-space: auto; mso-list: l0 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Plisados, </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 68.2pt; mso-add-space: auto; mso-list: l0 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->De bolsa, </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 68.2pt; mso-add-space: auto; mso-list: l0 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Absolutos, denominados HEPA, </div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 32.2pt; mso-add-space: auto; mso-list: l0 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Filtros electrostáticos</div>
<div class="MsoNormal">
<b><span style="text-transform: uppercase;">Refrigeración
y Deshumectación<o:p></o:p></span></b></div>
<div class="MsoNormal">
La refrigeración se consigue forzando el aire a pasar por
una batería de serpentín en el cual hay refrigerante evaporándose “equipos de
expansión directa” o agua fría “equipos de expansión indirecta” </div>
<div class="MsoNormal">
La batería de refrigeración trabaja a una temperatura
inferior al punto de rocío, parte del vapor contenido es condensado en la
superficie de los serpentines y esa agua es recogida en una bandeja
eliminándose por cañería al sistema de desagüe cloacal mediante un cierre
hidráulico (sifón o pileta de piso).</div>
<div class="MsoNormal">
<b><span style="text-transform: uppercase;"> Calefacción<o:p></o:p></span></b></div>
<div class="MsoNormal">
El aire es calentado en una batería de calefacción,
normalmente agua caliente proveniente de una caldera. En equipos de expansión
directa también se suele emplear la misma batería de refrigeración para
calentar en invierno mediante inversión del ciclo o boba de calor. No es
conveniente que el calor supere los 80°C, ya que se produce el tostamiento del
polvo depositado sobre las serpentinas generando hollín.</div>
<div class="MsoNormal">
<b><span style="text-transform: uppercase;"> Humectación<o:p></o:p></span></b></div>
<div class="MsoNormal">
Luego de calentar el aire se lo hace pasar por humectador,
son dispositivos que evaporan agua mediante una resistencia eléctrica, este
procedimiento se realiza en zonas climáticas muy secas y frías, no en zonas
templadas y húmedas como en la Ciudad de Bs As. </div>
<div class="MsoNormal">
<b><span style="text-transform: uppercase;">Circulación</span></b></div>
<div class="MsoNoSpacing">
Una vez tratado el aire se lo impulsa al interior
mediante ventiladores centrífugos que emiten bajo nivel de ruido. Los conductos
son de chapa galvanizada, aisladas. La inyección de aire se realiza por medio
de rejas en muros o difusores en cielorrasos. </div>
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-583983353596736922013-02-16T04:38:00.001-08:002013-02-16T04:38:03.507-08:00CONCEPTOS DE DISEÑO<br />
<h1>
<span style="font-size: small;">Lo primero que debe analizarse es el emplazamiento de la
sala de maquinas o el recintos de los equipamientos donde se albergan, estos
espacios deben definirse en función de los tipos de equipos, cañerías, conductos,
tableros, evaluando la accesibilidad para facilitar la operación y el
mantenimiento. El código municipal de Buenos Aires establece:</span></h1>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l5 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Ventilación exterior, mediante vanos o conductos
de área útil o mayor de 0.2m2, debe asegurarse 5 renovaciones del volumen total
del aire por hora.</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l5 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Superficie de paso no menor a 50cm alrededor de
la mitad del perímetro de cada equipo y una altura de 1 m sobre los aparatos en
los que sea necesario trabajar o inspeccionar.</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l5 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Si existen calderas no deben tener comunicación
con los recintos de medidores de gas, ni contener a estos.</div>
<div class="MsoNormal" style="text-indent: 18.0pt;">
<b><span style="text-transform: uppercase;">REQUISITOS PARTICULARES DE
DISEÑO<o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l2 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Estética
del edificio</b>, la instalación de aire debe formar parte del edificio sin
desvirtuar el hecho arquitectónico. </div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Simpleza
de la instalación</b>, la capacidad de los equipos debe ser mínima exigida,
seriada y que tengan una fácil y rápida instalación. </div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Mantenimiento
mínimo</b>, concebido a ciertas rutinas periódicas.</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Facilidad
de ampliación</b>, debe estar proyectada de modo de ir acompañando las posibles
ampliaciones del edificio.</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Confiabilidad
de funcionamiento</b>, se basa en la premisa de la continuidad del servicio,
instalando equipamientos con una redundancia (n+1), para que siempre exista en
la instalación un equipo de reserva disponible y expectante, con controles que
permitan permutar automáticamente el orden de funcionamiento.</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Evitar
trasmitir ruidos molestos al interior y vecinos externos</b>, Los elementos que
generan vibraciones deben estar montados sobre bases antivibratorias y la unión
de los ventiladores con la red de conductos, debe efectuarse mediante juntas
elásticas de lona o plásticas.</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>AHORRO
ENERGETICO, </b>Para contar con una instalación eficiente, es indispensable que
la instalación y el proyecto del edificio sean pensados en conjunto. </div>
<div class="MsoListParagraphCxSpMiddle">
Las instalaciones de aire acondicionado
requieren un consumo elevado de energía eléctrica, por lo que su reducción es
una de las premisas BASICAS en los criterios de diseño sustentable alcanzando
niveles internacionales como las L.E.D. </div>
<div class="MsoListParagraphCxSpMiddle">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi5ztaHOLW_ETSJTh68T4cyyt_E8TalCtvTWqiQVkBfRY_CiVDo4P3FUJdpTvGq-WDmIydxgDcHoyQztwLv4Q2T764KHVwPJKILm2giXFYDVs5LMZw35qShH_2maSust4u3yfFdRotMLvo/s1600/niveles-agbc.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi5ztaHOLW_ETSJTh68T4cyyt_E8TalCtvTWqiQVkBfRY_CiVDo4P3FUJdpTvGq-WDmIydxgDcHoyQztwLv4Q2T764KHVwPJKILm2giXFYDVs5LMZw35qShH_2maSust4u3yfFdRotMLvo/s1600/niveles-agbc.jpg" height="96" width="320" /></a></div>
<div class="MsoListParagraphCxSpMiddle">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 54.0pt; mso-add-space: auto; mso-list: l0 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><i>Proyecto
del edificio</i>, debe contar con la adecuada aislación térmica en muros y
techos, pisos, debe estudiarse la correcta disposición de los locales según su
uso, su forma, su orientación y las protecciones solares. Debe contar con un
sistema de iluminación natural o artificial de bajo consumo y potencia disipada
al interior.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 54.0pt; mso-add-space: auto; mso-list: l0 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><i>Eficiencia
del equipamiento</i>, en el diseño de equipos de refrigeración, debe tenerse en
cuenta para aumentar el rendimiento, que las temperaturas de condensación deben
ser las más bajas y las de evaporación las más altas posibles. Por ejemplo, los
equipos enfriados por agua con torre de enfriamiento tienen mayor rendimiento
que los enfriados por aire porque su temperatura de condensación es menor y por
otra parte, las unidades condensadores o enfriadoras de agua rinden mas, cuanto
mayor es la temperatura de evaporación o del agua de distribución. Para
determinar la eficiencia energética de los equipamientos, suele aplicarse un
coeficiente de performance denominado COP</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 90.0pt; mso-add-space: auto; mso-list: l0 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span lang="EN-US" style="font-family: "Courier New"; mso-ansi-language: EN-US; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><span lang="EN-US">COP
= KW (frig, watts) / KW (elec, watts)<o:p></o:p></span></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 90.0pt; mso-add-space: auto;">
COP, debe estar comprendido entre 2.5 a 3</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l3 level1 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><i>Cargas
parciales</i>, las instalaciones son dimensionadas para que satisfagan las
cargas máximas, pero deben poder mantener el ambiente climatizado en las
distintas variables de menor exigencia
que puedan producirse. Son denominadas cargas parciales, lo que lleva a la
necesidad de considerar el desdoblamiento de la instalación para satisfacer
pequeñas cargas parciales. Dividiendo los equipos en dos o varias unidades, así
las maquinas rinden más cuando están funcionando al máximo de su capacidad y en
este caso, operaria a cargas parciales, una sola, mientras que las restantes
permanecerían expectante para acoplarse en caso de aumentar las cargas. Además
se dispone de mayor seguridad en el servicio en caso de fallas y se aumenta la
vida útil de la instalación.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l3 level1 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><i>Emplazamiento</i>,
cuando se centraliza la instalación en una gran sala de maquinas en un
subsuelo, alejada del ambiente a servir, requieren largos tendidos de conductos
y de grandes dimensiones, que ocupan áreas útiles y originan problemas
constructivos. El problema se agudiza si el equipo es todo aire, donde los
conductos de aire pueden tomar una exagerada dimensión. Es conveniente
descentralizar las unidades de tratamiento de aire y ubicarlas cercanas a los
locales a acondicionar, para que desde allí se efectué la distribución del aire
mediante las conductos</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l3 level1 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><i>Zonificación</i>,
consiste en agrupar el acondicionamiento de todos aquellos ambientes del
edificio cuyas cargas térmicas varían en forma similar. Los principales
factores son:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l4 level1 lfo5; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Orientación</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l4 level1 lfo5; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Horarios de uso</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l4 level1 lfo5; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Disipaciones internas y condiciones
psicométricas, diversidad de cargas térmicas interiores debidas a maquinas o
dispositivos que disipan calor al ambiente, como es el caso de un centro de
cómputos lindero con una oficina con personal.</div>
<div class="MsoNormal" style="margin-left: 35.4pt; text-indent: 18.0pt;">
Zonificación en
edificios en edificios de oficinas</div>
<div class="MsoListParagraph" style="margin-left: 71.4pt; mso-add-space: auto; mso-list: l1 level1 lfo6; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Zona perimetral, es la distancia de 5 mts a
partir del muro exterior, que se considera expuesta a la acción variable del
clima y del sol, desde un máximo en verano por radiación solar, trasmisiones de
calor, disminuyendo luego en las estaciones intermedias hasta presentarse como
una zona con pérdida de calor.</div>
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-18762526164832675232013-02-16T04:34:00.004-08:002013-02-16T04:34:44.526-08:00UNIDADES<br />
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<b><span style="text-transform: uppercase;">Intensidad
de calor</span></b></div>
<div class="MsoNormal">
Se relaciona con el movimiento molecular, a mayor movimiento
se producen coaliciones que generan energía térmica la cual puede ser medida
como variación de temperatura mediante artefactos.</div>
<div class="MsoNormal">
Para mensurar la intensidad de calor se utilizan dos
escalas:</div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l2 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Celsius</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l2 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Fahrenheit </div>
<div class="MsoNormal">
<b><span style="text-transform: uppercase;">Cantidad
de calor</span></b></div>
<div class="MsoNormal">
Indica el contenido total de energía calórica.</div>
<div class="MsoNormal">
Un trozo de hierro al rojo tiene una temperatura mayor que
un cubo de agua caliente, pero este seguramente tiene almacenado más cantidad
de calor o energía calórica. La cantidad de calor de un cuerpo es función de su
masa y temperatura, o sea del número de moléculas que lo componen y su
velocidad media molecular</div>
<div class="MsoNormal">
Para mensurar la cantidad de calor se ha establecido un
valor característico que depende de la composición física y química de cada
material:</div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l0 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Calor específico (Ce), es la cantidad de calor
necesario para elevar en 1 °C la temperatura de la unidad de masa de una
sustancia a presión atmosférica normal. Como unidad de referencia se utiliza el
agua, cuyo Ce:1, es entonces, la cantidad de calor necesaria para elevar la
temperatura de 1kg de agua en 1°C a presión atmosférica normal. A esa cantidad
de calor aportada se la denomina Kcal, entonces: Ce: Kcal / Kg . °C</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l0 level2 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span lang="EN-US" style="font-family: "Courier New"; mso-ansi-language: EN-US; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><span lang="EN-US">1kcal:
4 BTU (British thermal unit), unidad inglesa<o:p></o:p></span></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l0 level2 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->1 kcal: 4.185 Joule : 4,185 KJ (sistema
internacional)</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l0 level2 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span lang="EN-US" style="font-family: "Courier New"; mso-ansi-language: EN-US; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><span lang="EN-US">1
kcal / h : 4.185 Joule / 3600 seg.: 1.16 Watt<o:p></o:p></span></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<b><span style="font-size: 14.0pt; line-height: 115%;">CALOR SENSIBLE Y CALOR LATENTE<o:p></o:p></span></b></div>
<div class="MsoNormal">
<b><span style="text-transform: uppercase;">Calor
sensible</span></b></div>
<div class="MsoNormal">
Se lo denomina cuando el agregado de calor a una sustancia
provoca un aumento de temperatura, que puede medirse con un termómetro</div>
<div class="MsoNormal">
Qs: Ce . m . (t1- t2)</div>
<div class="MsoNoSpacing">
Donde:</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l3 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->Qs:
cantidad de calor sensible agregado o sustraído (Kcal)</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l3 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->Ce:
calor especifico de la sustancia (Kcal / kg . °C)</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l3 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->M:
masa (Kg)</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l3 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->(t1-t2):
diferencia de temperatura (°C)</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 18.0pt;">
<b><span style="text-transform: uppercase;">Calor Latente<o:p></o:p></span></b></div>
<div class="MsoNormal">
Se lo denomina cuando el agregado o sustracción del calor no
origina un cambio en la temperatura ya que está materializando un cambio de
estado físico. No puede verificarse con un termómetro</div>
<div class="MsoNormal">
Ql: Cl . m</div>
<div class="MsoNoSpacing">
Donde:</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l1 level1 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->Ql:
cantidad de calor latente agregado o sustraído (Kcal)</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l1 level1 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->Cl:
calor latente de vaporización o fusión
(Kcal / kg )</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l1 level1 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->M:
masa (Kg)</div>
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-56368864996425889812013-02-16T04:34:00.000-08:002014-09-05T09:38:21.827-07:00BALANCE TÉRMICO ANÁLISIS DE CARGAS TÉRMICAS<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiysouOv5klGG5Fq0w59FsqiVhVQ8RWhjV3FPmYS8eXMi1__Gyre9TqrbHryLEpIth1p8qKdUMA_8lxuDDNXLCU7nVoFJjo6t9IA5OTGES8WBY9y-w3ZiAZSriT4dqFmveLdSjk63JSKq4/s1600/tarjetas_originalimprenta_02.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiysouOv5klGG5Fq0w59FsqiVhVQ8RWhjV3FPmYS8eXMi1__Gyre9TqrbHryLEpIth1p8qKdUMA_8lxuDDNXLCU7nVoFJjo6t9IA5OTGES8WBY9y-w3ZiAZSriT4dqFmveLdSjk63JSKq4/s1600/tarjetas_originalimprenta_02.png" height="204" width="320" /></a></div>
<span style="float: left;"><span style="font-family: Arial, Helvetica, sans-serif;">Tel: (03543) 15-553112 Cordoba / (011) 15-5496-1322 Buenos Aires</span></span><br />
<span style="font-family: Arial, Helvetica, sans-serif;"> mail: <a href="mailto:info@nativoarq.com.ar">info@nativoarq.com.ar</a> / diazfernandoariel@yahoo.com.ar </span><br />
<span style="font-family: Arial, Helvetica, sans-serif;">SITIO WEB: http://www.nativoARQ.com.ar </span><br />
<br />
REALIZAMOS PROYECTOS Y OBRAS, SU CONSULTA NO MOLESTA!<br />
<h1>
<span style="font-size: small;">Su objetivo es:</span></h1>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Análisis del comportamiento térmico de un local
o una zona.</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Cómputo del ingreso de calor, obteniendo la
cantidad de calor total del local a retirar para lograr el confort térmico
deseado.</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Elección de la tipología constructiva apropiada.</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->AHORRO ENERGÉTICO... EDIFICIOS SUSTENTABLES.</div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">TRASMISION DE CALOR<o:p></o:p></span></b></div>
<div class="MsoNormal">
Se lo define como la cantidad de calor en kilocalorías que
se trasmite en una hora a través de 1 m2 de superficie. Los coeficientes K
están tabulados por la Norma IRAM 11.601. </div>
<div class="MsoNormal">
Para el cálculo del coeficiente de transmitancia térmica
total K de un cerramiento simple:</div>
<div class="MsoNormal">
Rt: 1 / K : Rsi +(e / λ ) + Rse</div>
<div class="MsoNoSpacing">
Donde:</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l2 level1 lfo5; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->Rt:
resistencia térmica total, inversa de K (m2 . °C / Kcal)</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l2 level1 lfo5; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->e:
espesor del ceramiento (m)</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l2 level1 lfo5; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->λ:
coeficiente de conductibilidad térmica
(Kcal / h . m. °C)</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l2 level1 lfo5; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->Rsi:
resistencia superficial interna (m2 . h . °C / Kcal)</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l2 level1 lfo5; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->Rse:
resistencia superficial externa (m2 . h . °C / Kcal)</div>
<div class="MsoNoSpacing">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">CARGAS DE AIRE ACONDICIONADO<o:p></o:p></span></b></div>
<div class="MsoNormal">
Es la cantidad de calor que hay que extraer en verano, o
incorporar en invierno, para mantener una temperatura y humedad prefijadas. Su
cálculo permite dimensionar la instalación. En verano se las denomina “cargas
de refrigeración” y en invierno “cargas de calefacción”</div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">CARGAS DE REFRIGERACION</span></b></div>
<div class="MsoNormal">
Las unidades que suelen utilizarse son:</div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l5 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Frigoría / hora = Kcal / hora</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l5 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Tonelada de refrigeración = 3024 Frigoría /
hora, es una unidad inglesa.</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l5 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->KW = 860 frigoría / hora</div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
Las cargas pueden clasificarse en:</div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l1 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b><span style="font-size: 12.0pt; line-height: 115%;">EXTERNAS del local</span></b>, son
las que provienen del exterior</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l1 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Trasmisión
del calor (qts)</b> : debido a la diferencia de temperatura entre el aire exterior
e interior a través de muros, techos y ventanas.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l1 level3 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Paredes y techos exteriores: es la cantidad de
calor trasmitido por efecto de la diferencia de temperatura.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto;">
<span lang="EN-US">qts = S . K . (</span>Δ<span lang="EN-US"> t )<o:p></o:p></span></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto;">
<span lang="EN-US">Donde:<o:p></o:p></span></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 144.0pt; mso-add-space: auto; mso-list: l1 level4 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->qts : ganancia de calor total por trasmisión (Kcal / hora)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 144.0pt; mso-add-space: auto; mso-list: l1 level4 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->S: superficie del muro o techo (m2)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 144.0pt; mso-add-space: auto; mso-list: l1 level4 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->K: coeficiente de transmitancia total del
cerramiento (Kcal / h . m2 . °C)</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 144.0pt; mso-add-space: auto; mso-list: l1 level4 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Δ t: diferencia de temperatura ext – int. (°C)</div>
<div class="MsoNoSpacing" style="margin-left: 142.2pt;">
<br /></div>
<div class="MsoNormal" style="margin-left: 106.2pt;">
Paredes y techos interiores:
puede suponerse una temperatura 3°C menos a la exterior en verano.</div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l1 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Radiación
(qrs)</b>: aporte por efecto invernadero y pasaje retardado sobre muros y
techos en virtud de la inercia térmica del material.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto;">
qrs = S.K.R</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto;">
Donde: </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 144.0pt; mso-add-space: auto; mso-list: l1 level4 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->S: superficie del cerramiento (m2)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 144.0pt; mso-add-space: auto; mso-list: l1 level4 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->K : coeficiente de transmisión térmica (Kcal / h
. m2)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 144.0pt; mso-add-space: auto; mso-list: l1 level4 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->R: coeficiente de radiación solar. Factor solar,
depende de:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 180.0pt; mso-add-space: auto; mso-list: l1 level5 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Angulo de incidencia</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 180.0pt; mso-add-space: auto; mso-list: l1 level5 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Horario</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 180.0pt; mso-add-space: auto; mso-list: l1 level5 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Orientación</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 180.0pt; mso-add-space: auto; mso-list: l1 level5 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Color, textura, acabado superficial</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 180.0pt; mso-add-space: auto; mso-list: l1 level5 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->protecciones</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 144.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto;">
Por efecto invernadero, todo el calor que penetro en el local queda
almacenado, por ese motivo, la protección solar de las ventanas constituye un
factor primordial para reducir las cargas de aire acondicionado de verano.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l1 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Cargas
por Ventilación o del sistema (qv)</b>: Calor proveniente del caudal de aire
exterior para satisfacer las necesidades de ventilación. Una parte en forma de
calor sensible y otra en forma de calor latente por la humedad. Depende del
número de personas, tipo de ocupación y actividad. </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto;">
V
= a% . C</div>
<div class="MsoNoSpacing" style="margin-left: 35.4pt; text-indent: 35.4pt;">
Donde:</div>
<div class="MsoNoSpacing" style="margin-left: 88.8pt; mso-list: l4 level1 lfo6; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->V:
caudal de ventilación, aire nuevo exterior (m3 / min).</div>
<div class="MsoNoSpacing" style="margin-left: 88.8pt; mso-list: l4 level1 lfo6; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->a:
porcentaje de aire nuevo (%)</div>
<div class="MsoNoSpacing" style="margin-left: 106.2pt;">
Locales con muchas personas:
25 al 30%</div>
<div class="MsoNoSpacing" style="margin-left: 106.2pt;">
<b>Edificios de oficinas: 15 al 25%<o:p></o:p></b></div>
<div class="MsoNoSpacing" style="margin-left: 106.2pt;">
Viviendas 10 al 20%</div>
<div class="MsoNoSpacing" style="margin-left: 88.8pt; mso-list: l4 level1 lfo6; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->C:
caudal de aire en circulación (m3/min)</div>
<div class="MsoListParagraph" style="margin-left: 72.0pt; mso-add-space: auto; text-indent: 34.2pt;">
C = QSi / 170 (m3/min)</div>
<div class="MsoNormal" style="margin-left: 70.75pt;">
<b>En la práctica, suele tomarse para edificios residenciales,
departamentos u oficinas un valor mínimo de V: ¿? m3/h persona. Cantidad de personas<o:p></o:p></b></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 72.0pt; mso-add-space: auto;">
qvs: (Kcal / h) = V . Pe . Ce . Δ t</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
Donde: <o:p></o:p></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 106.2pt; mso-add-space: auto;">
V: caudal de ventilación, aire nuevo exterior (m3 / h).</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 106.2pt; mso-add-space: auto;">
Pe: peso especifico del aire 1.19 (kg / m3)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 106.2pt; mso-add-space: auto;">
Ce: calor especifico del aire 0.24 (Kcal / kg . °C)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 106.2pt; mso-add-space: auto;">
Δ
t: diferencial temperatura del aire
exterior e interior (°C)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<span lang="EN-US">qvl: (Kcal / h) = V . Pe . </span>L . Δ Ha</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
Donde: <o:p></o:p></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 106.2pt; mso-add-space: auto;">
V: caudal de ventilación, aire nuevo exterior (m3 / h).</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 106.2pt; mso-add-space: auto;">
Pe: peso especifico del aire 1.19 (kg / m3)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 106.2pt; mso-add-space: auto;">
L: calor latente de vaporización 0.575 (Kcal / kg)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 106.2pt; mso-add-space: auto;">
Δ
Ha: diferencial humedad de humedades
absolutas del aire exterior (gr / kg)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 106.2pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l1 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b><span style="font-size: 12.0pt; line-height: 115%;">INTERNAS del local</span></b>, son
las que se originan en el interior:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l1 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Personas
(Qps)</b>: disipan calor sensible y latente, por el aporte de humedad de la
sudoración y respiración</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<b>Qps </b>= N° personas . Qs / hora
de permanencia</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
Donde: </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 106.2pt; mso-add-space: auto;">
N : personas: según factor de ocupación. Datos del código de edificación
artículo 4721</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 106.2pt; mso-add-space: auto;">
Qs : Kcal o Watts por hora y por persona, dato de tabla según la
actividad.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 106.2pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 106.2pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l1 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Personas
(Qpl)</b>: </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<b>Qpl </b>= N° personas . Ql / h.per</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
Donde: </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 106.2pt; mso-add-space: auto;">
N : personas: según factor de ocupación. Datos del código de edificación
artículo 4721</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 106.2pt; mso-add-space: auto;">
Ql : Kcal o Watts por hora y por persona, dato de tabla según la
actividad.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l1 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Iluminación
(Qis):</b> es calor sensible. Cuando no hay datos se puede estimar 15 a 25,
Watts / m2, para iluminación fluorescente se agrega un 20% por las calor que
irradian los balastros.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
1 watt = 0.86 kcal/h</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l1 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Otras
fuentes: maquinas, motores, etc. (Qse): </b>del tipo de maquinaria pueden
modificar la temperatura y / o la humedad</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
Motor: Qms= 73 kcal / h . HP</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
Cafeterias: Qcs= 227 kcal / h Qcl=
55 kcal / h</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<span lang="EN-US">Compotator: Qcs = 250
kcal/h<o:p></o:p></span></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<span lang="EN-US">Qse: Qms+Qcs+Qcs<o:p></o:p></span></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
Qle: Qcl</div>
<div class="MsoListParagraphCxSpLast">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">CARGA TOTAL DE CALOR SENSIBLE (qS)<o:p></o:p></span></b></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
QS=Qst + Qsr + Qsv + Qsp + Qsi +
Qse (Kcal / h) + 10%</div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">CARGA TOTAL DE CALOR LATENTE (qS)<o:p></o:p></span></b></div>
<div class="MsoNormal" style="tab-stops: 213.9pt; text-indent: 35.4pt;">
QL= Qlv + Qlp +
Qle (Kcal / h) + 5%</div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">CARGA TOTAL DE CALOR (qT)<o:p></o:p></span></b></div>
<div class="MsoNoSpacing" style="text-indent: 35.4pt;">
Q total: QS +QL (Kcal / h)</div>
<div class="MsoNormal" style="tab-stops: 213.9pt; text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="tab-stops: 213.9pt; text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">Numero
Índice</span></b>: Qtotal / Volumen del local analizado (Kcal . m3 / h )</div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">SUPOSICIONES DEL CÁLCULO<o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 88.8pt; mso-add-space: auto; mso-list: l3 level1 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Puertas: se estiman dentro del área de la pared,
dada que las diferencias son despreciables.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 88.8pt; mso-add-space: auto; mso-list: l3 level1 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Piso sobre tierra: no se considera ganancia de
calor ya que esta más frio que el aire interior.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 88.8pt; mso-add-space: auto; mso-list: l3 level1 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Locales no acondicionados: se los considera con
una temperatura menor de 3 °C respecto al exterior.</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 88.8pt; mso-add-space: auto; mso-list: l3 level1 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Locales acondicionados: no se considera ganancia
de calor.</div>
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com1tag:blogger.com,1999:blog-3273325622788575209.post-60471563358531354142013-02-16T04:32:00.002-08:002013-02-16T04:32:37.957-08:00PSICROMETRIA<br />
<h1>
<span style="font-size: small;">La psicrometría es la ciencia que estudia las propiedades
físicas del aire.</span></h1>
<div class="MsoNormal">
<span style="font-size: 19px; line-height: 21px;"><b>COMPOSICIÓN</b></span><b><span style="font-size: 14.0pt; line-height: 115%;"> DEL AIRE</span></b></div>
<div class="MsoNormal">
El aire atmosférico es una mezcla de aire seco y vapor de
agua. La cantidad de agua en el aire es extremadamente variable y constituye la
humedad atmosférica.</div>
<div class="MsoNormal">
<b><span style="font-size: 14.0pt; line-height: 115%;">CONTENIDO DE HUMEDAD</span></b></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">HUMEDAD ESPECIFICA O
absoluta (</span>he<span style="text-transform: uppercase;">)<o:p></o:p></span></b></div>
<div class="MsoNormal">
El aire siempre tiene cierta cantidad de humedad y se mide
en gramos de vapor de agua por Kg de aire seco (gr / kg), se la denomina humedad especifica (he). Cuando el aire
contiene el máximo posible de humedad, está saturado. Cuanto más cálido es el
aire, mayor es el vapor de agua que se necesita para saturarlo. </div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l2 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->a 0°C se necesita 4 gr/kg de humedad especifica
(he) para saturar el aire, mientras que</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->a 10°C se necesita 7.6 gr/kg,</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l2 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->y a 20°C se necesita 14.7 gr/kg.</div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">HUMEDAD RELATIVA (HR)<o:p></o:p></span></b></div>
<div class="MsoNormal">
Es el porcentaje % de saturación del aire a cualquier
temperatura. El aire saturado tendrá un HR de 100%. Si el aire atmosférico
tiene 7.35 gr/kg de humedad especifica (he) a la temperatura de 20°C, la
humedad relativa (HR) sería del 50%, dado que tendría la mitad de he que tendría
si estuviera saturado.</div>
<div class="MsoNormal">
HR :( he / hes ).100%</div>
<div class="MsoNormal">
según el ejemplo 7.35
gr/kg / 14.7 gr/kg : 0.5, o 50% de HR</div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNoSpacing">
Donde:</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l6 level1 lfo7; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->HR:
humedad relativa (%)</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l6 level1 lfo7; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->he:
humedad especifica real a la temperatura (gr/kg)</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l6 level1 lfo7; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->hes:
humedad especifica de saturación e esa misma temperatura (gr/kg)</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<span style="text-transform: uppercase;"><b>MEDICIÓN</b></span><b><span style="text-transform: uppercase;"> DE LA HUMEDAD<o:p></o:p></span></b></div>
<div class="MsoNormal">
Se utiliza el Psicrómetro para medir la humedad. Son dos
termómetros, uno con el bulbo seco, denominado termómetro seco y el otro con un
bulbo recubierto por un lienzo empapado en agua denominado termómetro húmedo.
Se hace circular aire mediante un pequeño ventilador hasta que la temperatura
de ambos se estabilice.</div>
<div class="MsoNormal">
<b>La temperatura del
bulbo húmedo (TBH)</b> es menor o igual a la <b>temperatura del bulbo seco (TBS),</b> este efecto se produce por la
evaporación del agua del lienzo en el aire ambiente. De esta manera, el lienzo
entrega al aire vapor este cambio de estado consume calor latente y hace bajar
la temperatura del bulbo húmedo.</div>
<div class="MsoNormal">
La cantidad de agua evaporada estará en función de la
capacidad del aire circundante de absorber humedad. Si el aire estuviera
saturado no admitirá mas humedad y por lo tanto ambos termómetros indicarían el
mismo valor. Cuanto mayor sea la diferencia entre ambos menor humedad relativa
tendrá el ambiente. </div>
<div class="MsoNormal">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgMp5Z7v-WJZpSR5tmLHQR72K33CsEh5EY0GyS8Pz4S-Lj1ReMKigDZnX0ufLXuXLwkBAQcgQUqh0iONbUkQWkmKBcwnx5Qg1DmcWV5Syk5SYZCYxn4LVtCwKE4zewYpBZ8tGT5R9ylI1U/s1600/psicrometro.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgMp5Z7v-WJZpSR5tmLHQR72K33CsEh5EY0GyS8Pz4S-Lj1ReMKigDZnX0ufLXuXLwkBAQcgQUqh0iONbUkQWkmKBcwnx5Qg1DmcWV5Syk5SYZCYxn4LVtCwKE4zewYpBZ8tGT5R9ylI1U/s1600/psicrometro.JPG" height="255" width="400" /></a></div>
<div class="MsoNormal">
<br /><!--[endif]--></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<span style="text-transform: uppercase;"><b>ÁBACO</b></span><b><span style="text-transform: uppercase;"> PSICROMETRICO<o:p></o:p></span></b></div>
<div class="MsoNormal">
El ábaco contiene todos los parámetros físicos de una mezcla
de aire húmedo por kg de aire seco, representándose en función de las
temperaturas del bulbo seco y humedades especificas, las humedades relativas y
temperaturas de bulbo húmedo.</div>
<div class="MsoNormal">
En una escala complementaria se halla la <b>ENTALPIA</b> (Kcal / kg), que es el
contenido total de calor del aire (Kcal) por kg de aire seco, el que puede ser
considerado como la suma del calor sensible del aire seco y el calor latente
del vapor de agua.</div>
<div class="MsoNormal">
Además se encuentran las líneas de <b>VOLUMEN ESPECIFICO</b> (m3 / kg), que relaciona el volumen del aire en
m3, con los kg de aire seco y es la inversa del peso especifico.</div>
<div class="MsoNormal">
La curva final de humedad relativa 100% indica el punto de
rocío del aire a esa temperatura<b>, la TBS
= TBH = TPR (temperatura de punto de rocío) y el aire está saturado</b>. Si una
superficie está más fría que la temperatura del punto de rocío, se produce
condensación de parte del vapor de agua del aire sobre esa superficie y si se
sigue enfriando se observa en el ábaco, como disminuye su contenido de humedad
especifica, se des-humidifica. </div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiLtNT9iSTpDIJz_BjEJi7UZucgin_CE193h-EvmY159eJg_x7YIgixKNp4OdHtK_W9JD3afeUl_u-IUNITLnYNL4nXDSBVNOVxhtd4f5pMEDOBiRCCVOilt5bDAlr176XlHb5s4f093CI/s1600/diagrama+psicrometrico1.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiLtNT9iSTpDIJz_BjEJi7UZucgin_CE193h-EvmY159eJg_x7YIgixKNp4OdHtK_W9JD3afeUl_u-IUNITLnYNL4nXDSBVNOVxhtd4f5pMEDOBiRCCVOilt5bDAlr176XlHb5s4f093CI/s1600/diagrama+psicrometrico1.jpg" height="282" width="400" /></a></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">FACTOR DE CALOR SENSIBLE<o:p></o:p></span></b></div>
<div class="MsoNormal">
Matematicamente es la relación que existe entre el calor
sensible (Qs) y el calor total (Qt) del local</div>
<div class="MsoNormal">
FCS = Qs / (Qs + Ql) = Qs / QT</div>
<div class="MsoNormal">
Indica las características que debe tener el aire que se
inyecta al local que se desea acondicionar. Su valor varía de 1 a 0. No tiene
unidad.</div>
<div class="MsoNormal">
El aire de mando que ingresa a un local a acondicionar debe
actuar como una “esponja de calor” absorbiendo calor sensible y latente en
determinadas proporciones FCS.</div>
<div class="MsoNormal">
Su escala señala el punto central del diagrama, donde FCS =1,
TBS = 26.5°C y HR=50%</div>
<div class="MsoNormal">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjpRouKsPhVJvtts0pMjsllQdC8AXQkpqtHbFAMQ9irmE2CrBlPYJASyEjqzSYzLonwr7R1zSLJbW5tqPP8wpijp46c5mHTSRgX4Eemc3RsuCU8YQcMU-ODZMNppZiZ1cnFuxt9Skx8gP0/s1600/diagrama+psicrometrico3.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjpRouKsPhVJvtts0pMjsllQdC8AXQkpqtHbFAMQ9irmE2CrBlPYJASyEjqzSYzLonwr7R1zSLJbW5tqPP8wpijp46c5mHTSRgX4Eemc3RsuCU8YQcMU-ODZMNppZiZ1cnFuxt9Skx8gP0/s1600/diagrama+psicrometrico3.jpg" height="282" width="400" /></a></div>
<div class="MsoNormal">
<b><span style="mso-fareast-language: ES-AR; mso-no-proof: yes; text-transform: uppercase;"><br /><!--[endif]--></span></b></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">VARIACIONES DE TEMPERATURA Y
HUMEDAD</span></b></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;"><br /></span></b></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhRUV86PKval40zyRUhUDxoIe73mHNxl_TgYDEri-P-lpdlt78_9wUuWLw-heSpFFaLCtEXkqcN4JB51Q8XQFFeTU750tOE4y8Vi6MakvEBvpRGvc1OckTxAgsqvzZA4hQTTXbacsGfOrk/s1600/diagrama+psicrometrico2.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhRUV86PKval40zyRUhUDxoIe73mHNxl_TgYDEri-P-lpdlt78_9wUuWLw-heSpFFaLCtEXkqcN4JB51Q8XQFFeTU750tOE4y8Vi6MakvEBvpRGvc1OckTxAgsqvzZA4hQTTXbacsGfOrk/s1600/diagrama+psicrometrico2.jpg" height="282" width="400" /></a></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;"><br /></span></b></div>
<div class="MsoNormal">
Lo que se busca en acondicionamiento de aire en verano es el
enfriamiento mas la deshumidificación.</div>
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-42027118185025645802013-02-16T04:25:00.000-08:002013-02-16T04:25:02.221-08:00CONFORT TÉRMICO<br />
<h1>
<span style="font-size: small;">CONFORT TÉRMICO</span></h1>
<div class="MsoNormal">
Las instalaciones de climatización deben proporcionar las
condiciones óptimas de bienestar, para que el mecanismo de regulación del
cuerpo humano disipe el calor con el mínimo esfuerzo.</div>
<div class="MsoNormal">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjrWbna_ZWpfppqklDCc_l7zrOaCuap69K19-i8ArXQ7t5AtZi7KvqmZJaXpdYfIbsCQ4g63mG7xaJYxlNwVy4ZH2u90KMpvGSoTUksZYz4znphvcJji5gCKaHlzk3XJ7XXyXN5UuCNNpE/s1600/ESTRATEGIAS+BIOCLIMATICAS+PASIVAS.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjrWbna_ZWpfppqklDCc_l7zrOaCuap69K19-i8ArXQ7t5AtZi7KvqmZJaXpdYfIbsCQ4g63mG7xaJYxlNwVy4ZH2u90KMpvGSoTUksZYz4znphvcJji5gCKaHlzk3XJ7XXyXN5UuCNNpE/s1600/ESTRATEGIAS+BIOCLIMATICAS+PASIVAS.jpg" height="282" width="400" /></a></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<b><span style="text-transform: uppercase;">CONDICIONES ATMOSFÉRICAS QUE AFECTAN AL
CONFORT<o:p></o:p></span></b></div>
<div class="MsoNormal">
La sensación de confort está relacionada con las condiciones
del clima del local. Los parámetros básicos a controlar son:</div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Temperaturas
del aire y superficies</b>, esta depende en gran parte de la ropa que usen, el
grado de actividad física y el contenido de humedad, pudiéndose considerar: </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l0 level2 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Invierno 18 – 23 °C (22°C y 50% HR)</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l0 level2 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Verano 23 – 27 °C (25°C y 50% HR)</div>
<div class="MsoNormal" style="margin-left: 35.4pt;">
Debe considerarse la temperatura
de las superficies del local que circundan el cuerpo humano, dado que afectan
la disipación de su calor por su calor radiante, estas superficies no deben
superar los 5 °C de diferencia con la temperatura interior.</div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Humedad
relativa</b>, una gran parte del calor del cuerpo humano se disipa por
evaporación a través de la piel, favoreciéndose con una humedad relativa del
aire baja durante todo el año en 50%. Las HR menores a 30% producen sensación
de resecamiento y sequedad en la piel, HR superiores a 70% causa nauseas debido
a la reducción de la capacidad de disipar calor por sudoración. </div>
<div class="MsoListParagraphCxSpMiddle">
<br /></div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Movimiento
del aire</b>, este incrementa la proporción de humedad y calor disipados,
admitiéndose una velocidad en zonas de permanencia de 6 a 8 m/min en invierno y
8 a 12 m/min en verano.</div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">CONDICIONES DE DISEÑO<o:p></o:p></span></b></div>
<div class="MsoNormal">
No se deben tomar condiciones extremas que originen
sobredimensionamientos. La sensación de confort suelen referirse a valores
estadísticos de personas confortables en un rango de 80 al 90%.</div>
<div class="MsoNormal">
Las temperaturas y HR optima para verano es de 25°C y 50%
HR, y en invierno de 22°C y 50% HR.</div>
<div class="MsoNormal">
Las condiciones exteriores a adoptar tampoco son las máximas
registradas, ya que suelen aparecer pocos días y en un lapsus corto de tiempo.
El criterio general es adoptar un promedio a las 15 hs en verano, que excluya
los valores extremos.</div>
<div class="MsoNormal">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgdbgBHZlQzhrwM0yQKpHXprZoqg6liY0rWhpCZCr3W2HPR7dQNL-ZUFT_nLasIL00xEXJJieIBfE8MKTpuJX3pEeKbY-gx7hs1q9a8ieTUN-Y4JiE1WQey0NUsH_gevjXM22y_Y5QJ-is/s1600/CONFORT+TERMICO,+CONDICIONES+DE+DISE%C3%91O.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgdbgBHZlQzhrwM0yQKpHXprZoqg6liY0rWhpCZCr3W2HPR7dQNL-ZUFT_nLasIL00xEXJJieIBfE8MKTpuJX3pEeKbY-gx7hs1q9a8ieTUN-Y4JiE1WQey0NUsH_gevjXM22y_Y5QJ-is/s1600/CONFORT+TERMICO,+CONDICIONES+DE+DISE%C3%91O.jpg" height="282" width="400" /></a></div>
<div class="MsoNormal">
<br /><!--[endif]--></div>
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-10727808889977847672013-02-15T10:41:00.002-08:002013-02-15T10:41:30.458-08:00LOS DISTINTOS ESTADOS DEL AIRE<br />
<h1>
<span style="font-size: small;">EN EL DIAGRAMA
PSICROMETRICO REPRESENTAMOS LOS DISTINTOS ESTADOS DEL AIRE</span></h1>
<div class="MsoNormal">
<br /></div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>I</b>:
Condiciones del aire en el interior del local.</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>E</b>:
Condiciones del aire en el exterior del local.</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>M</b>:
Condiciones del aire de mezcla a la entrada de la unidad acondicionadora de
aire (Aire interior / Aire exterior).</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>C</b>:
Condiciones del aire de mezcla a la salida de la unidad acondicionadora de aire
(serpentina evaporadora).</div>
<div class="MsoNormal">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhns3W2OWQUJjhDXNVynnh35J5qHdkP1bOD1nmPU9pVtyGqsM4CvPskuemT-hYWJDBO-LPFSi8Xiqk8mdXoJUVuPJAo5uNuem3A9fB5QUyBH6I795__a3yCg-vZON-_MKu7lK-w8REml1E/s1600/puntos+de+analisis.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhns3W2OWQUJjhDXNVynnh35J5qHdkP1bOD1nmPU9pVtyGqsM4CvPskuemT-hYWJDBO-LPFSi8Xiqk8mdXoJUVuPJAo5uNuem3A9fB5QUyBH6I795__a3yCg-vZON-_MKu7lK-w8REml1E/s1600/puntos+de+analisis.JPG" height="227" width="320" /></a></div>
<div class="MsoNormal">
<o:p><br /></o:p></div>
<div class="MsoNormal">
<o:p><br /></o:p></div>
<div class="MsoNormal">
Primer paso, Ubicamos los puntos “I” y “E”, son datos
tabulados o criterios de diseño.</div>
<div class="MsoNormal">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjjU6HcZvpb7mEnWiCUYBn1gmGd7iuXV8BnfigYkmak5NDeBHSm8ucTTvlyqA3WKuVlEarx1KsnjviypNTc9pssHDM6mcAwrDtAIDjlQz4jB2hMzuHgDywl7rGDM1ib_qflTPlq1tyF_0s/s1600/UBICACION+DE+PUNTOS+E+Y+I.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjjU6HcZvpb7mEnWiCUYBn1gmGd7iuXV8BnfigYkmak5NDeBHSm8ucTTvlyqA3WKuVlEarx1KsnjviypNTc9pssHDM6mcAwrDtAIDjlQz4jB2hMzuHgDywl7rGDM1ib_qflTPlq1tyF_0s/s1600/UBICACION+DE+PUNTOS+E+Y+I.jpg" height="282" width="400" /></a></div>
<div class="MsoNormal">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
</div>
<div class="MsoNormal">
<br /><!--[endif]--></div>
<div class="MsoNormal">
Segundo, ubicamos que condiciones debería tener el aire en
la cámara de mezcla.</div>
<div class="MsoNormal">
<br /><!--[endif]--></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjr87THv7KpnkoRGY10t47Oyltmo46GKbT3Da-ROUTSm8Xnd74vkUOKB9PrrUY49vVcnwlbpqsIFm7FiHD8G6brFXuSPPmLE9Y0NtKBy_l3j59V7h62iSKCFz3ApoHcr5K0KpcZNh0Znvo/s1600/CONDICIONES+DEL+AIRE+DE+MEZCLA+PUNTO+M.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjr87THv7KpnkoRGY10t47Oyltmo46GKbT3Da-ROUTSm8Xnd74vkUOKB9PrrUY49vVcnwlbpqsIFm7FiHD8G6brFXuSPPmLE9Y0NtKBy_l3j59V7h62iSKCFz3ApoHcr5K0KpcZNh0Znvo/s1600/CONDICIONES+DEL+AIRE+DE+MEZCLA+PUNTO+M.jpg" height="282" width="400" /></a></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<o:p> </o:p> </div>
<div class="MsoNormal">
<o:p> </o:p> </div>
<div class="MsoNormal">
Tercero, trazamos desde el valor de F.C.S. al punto central
del diagrama psicométrico una recta.</div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<br /><!--[endif]--></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgZoqtUpMZkzLEa1YfvFSimMMR_y0aNpimxbcid-NVjDlQnk3Lk2t7nfGPaFxgscw3Hu8VtOLKiF-STWN05BEmLmuAkHV6iTnaKjG_NGenGg32aUmxbJC0vko5We12A0FDYxGZDGChhEM4/s1600/DETERMINACION+DE+FCS+Y+SU+RECTA.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgZoqtUpMZkzLEa1YfvFSimMMR_y0aNpimxbcid-NVjDlQnk3Lk2t7nfGPaFxgscw3Hu8VtOLKiF-STWN05BEmLmuAkHV6iTnaKjG_NGenGg32aUmxbJC0vko5We12A0FDYxGZDGChhEM4/s1600/DETERMINACION+DE+FCS+Y+SU+RECTA.jpg" height="282" width="400" /></a></div>
<div class="separator" style="clear: both; text-align: center;">
<br /><a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh-N66G_GUWq6eGh9zJQMsx7qIA0JKjG3xUFjW4nPkTq7aOqq_Q01zvU6Cj-_9ecd6r85zV7lJLl40Cx-PiBEold9E-uqVOp68lQGgxbMyprTsu-KirZsYQoP0rfPejHNvj8FMb2zj011s/s1600/DETERMINACION+DEL+PUNTO+C.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh-N66G_GUWq6eGh9zJQMsx7qIA0JKjG3xUFjW4nPkTq7aOqq_Q01zvU6Cj-_9ecd6r85zV7lJLl40Cx-PiBEold9E-uqVOp68lQGgxbMyprTsu-KirZsYQoP0rfPejHNvj8FMb2zj011s/s1600/DETERMINACION+DEL+PUNTO+C.jpg" height="282" width="400" /></a></div>
<div class="MsoNormal">
<br /><!--[endif]--></div>
<div class="MsoNormal">
Lo que se desea obtener con dicho análisis es:</div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>W</b>:
PESO DEL AIRE A CIRCULAR Kg / h</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>C A M:</b>
CAUDAL DE AIRE DE MANDO m3 / h</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>C A E:</b>
VERIFICACIÓN DEL CAUDAL DE AIRE EXTERIOR</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>R:</b>
CALOR A SUSTRAER POR EL EQUIPO Kcal / h TR CARGA DE REFRIGERACION TR</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l0 level2 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span lang="EN-US" style="font-family: "Courier New"; mso-ansi-language: EN-US; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><span lang="EN-US">1
Kcal/h = 1 Frig/h = 1,16 Watt<o:p></o:p></span></div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l0 level2 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->3.024 Kcal/h = 1 TR</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l0 level2 lfo1; text-indent: -18.0pt;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhSyAJhx3kSRnnG8fdXxu3yuBrw79qpvmFgOmqiF9ot2TvcAxpioauN4dYg2sZxiDY-NqlPGBROueWtoALHLC0ZjV3M1O3A0ej4BazaplGZPWuvSZyr_O2v8LUDsQQJiscPxKhcIM20yNM/s1600/DETERMINACION+DE+LOS+PARAMETROS+DEL+PUNTO+C.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhSyAJhx3kSRnnG8fdXxu3yuBrw79qpvmFgOmqiF9ot2TvcAxpioauN4dYg2sZxiDY-NqlPGBROueWtoALHLC0ZjV3M1O3A0ej4BazaplGZPWuvSZyr_O2v8LUDsQQJiscPxKhcIM20yNM/s1600/DETERMINACION+DE+LOS+PARAMETROS+DEL+PUNTO+C.jpg" height="282" width="400" /></a></div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l0 level2 lfo1; text-indent: -18.0pt;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiyhcjvhytwurErK-syQ7MqM8d3gaqK50ToNKjavK23xhlIPxP2RwNtleqO6LOr3OeDnJWSMhwHGolgYdvagnohJbHsLlQOBdhb3odFXxDzfgLXJu6E6lBwjU5DjI91vxaOXtiTLGSaFFQ/s1600/puntos+de+analisis+2.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiyhcjvhytwurErK-syQ7MqM8d3gaqK50ToNKjavK23xhlIPxP2RwNtleqO6LOr3OeDnJWSMhwHGolgYdvagnohJbHsLlQOBdhb3odFXxDzfgLXJu6E6lBwjU5DjI91vxaOXtiTLGSaFFQ/s1600/puntos+de+analisis+2.JPG" height="198" width="320" /></a></div>
<div class="MsoNormal">
<br /><!--[endif]--></div>
<div class="MsoNormal" style="margin-left: 106.2pt;">
<br /><!--[endif]--></div>
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-24740732785183777482013-02-15T10:30:00.000-08:002013-02-15T10:30:09.412-08:00DISPOSITIVOS DE ENFRIAMIENTO<br />
<h1>
<span style="font-size: small;">DISPOSITIVOS DE ENFRIAMIENTO</span></h1>
<div class="MsoNormal">
La refrigeración es el proceso de extraer el calor del aire
interior de un edificio mediante una sustancia refrigerante cuya temperatura es
inferior. De esa manera se produce la cesión de calor de la fuente de mayor
temperatura, que es el interior del local, a la de menor temperatura que es el
refrigerante.</div>
<div class="MsoNormal">
Para efectuar la refrigeración mecánica se aplican las propiedades
de cambios de estado físico de las sustancias, como ser la vaporización cuando absorbe
calor, pasando del estado liquido al vapor, o la condensación cuando se produce
el proceso inverso. </div>
<div class="MsoNoSpacing">
Siguiendo el principio de la producción de frio se basa
en las Leyes Fundamentales de los Gases</div>
<div class="MsoNoSpacing">
PRESIÓN – VOLÚMEN- TEMPERATURA</div>
<div class="MsoNoSpacing">
Gay - Lussac</div>
<div class="MsoNoSpacing">
V (Constante) = P/T (Constante)</div>
<div class="MsoNoSpacing">
Boyle - Mariotte</div>
<div class="MsoNoSpacing">
Temperatura Constante</div>
<div class="MsoNoSpacing">
P x V = Constante</div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
Este ciclo se realiza por:</div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Compresión, donde el vapor es aspirado o
succionado por un compresor </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Absorción, donde el vapor es absorbido por otra
sustancia.</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Evaporativa,</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">CICLO DE REFRIGERACION POR
COMPRESION<o:p></o:p></span></b></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;"><br /></span></b></div>
<div class="MsoNormal">
Se utiliza un refrigerante (R22) que hierve a presión
atmosférica normal a – 40°C y para controlar que se vaporice a 5 °C se lo
comprime hasta 6 atmosferas, aproximadamente.</div>
<div class="MsoNormal">
El procedimiento consiste en succionar el vapor refrigerante
y comprimirlo hasta 20 atmosferas. Esto calienta el gas a 50°C. Este gas a alta
temperatura y presión se lo expone a una temperatura de aire exterior de 35°C
donde se fuerza el intercambio de calor latente mediante un ventilador. (35°C
constituye normalmente la condición de diseño exterior de una instalación de
A°A° en verano para Bs As, son datos tabulados). El gas se condensa al ceder su
calor latente al exterior, que es más frio, pasando del estado de vapor a líquido,
a la misma temperatura de 50°C y a la misma presión de 20 atmosferas. </div>
<div class="MsoNormal">
Esta temperatura surge porque debe estar 15°C por encima de
la temperatura exterior facilitando la transferencia de calor latente.</div>
<div class="MsoNormal">
Este líquido se lo devuelve al recipiente inicial a través
de una válvula de expansión que provoca una brusca reducción de presión de 20 a
6 atmosferas, en su expansión repentina hace que el líquido caliente se enfríe
generándose un vapor con una pequeña cantidad de líquido denominado flash-gas.</div>
<div class="MsoNormal">
Este flash-gas se lo hace pasar por una serpentina de cobre
con aletas de aluminio en contacto con el aire interior, donde, ventilador
mediante, absorbe calor sensible calentándose y vaporizándose lo poco que se
filtro como liquido, generándose así nuevamente un gas a 6 atmosferas de
presión y 5°C que nuevamente es absorbido por el compresor.</div>
<div class="MsoNormal">
La temperatura del evaporador debe no ser menor a 5°C porque
se genera el riesgo del congelamiento del agua de condensado producida por la
deshumectación aire interior.</div>
<div class="MsoNormal">
Se distinguen las siguientes partes del ciclo:</div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Refrigerante</b>:
R22, R410, R407c y variables, todos deben tener:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 91.2pt; mso-add-space: auto; mso-list: l0 level5 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Temperatura de ebullición bajas.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 91.2pt; mso-add-space: auto; mso-list: l0 level5 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Bajas presiones de trabajo.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 91.2pt; mso-add-space: auto; mso-list: l0 level5 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->No deben ser toxico, explosivos, inflamables,
corrosivos ni irritantes.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 91.2pt; mso-add-space: auto; mso-list: l0 level5 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Deben ser inodoro.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 91.2pt; mso-add-space: auto; mso-list: l0 level5 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Debe ser miscible, con el aceite de lubricación
empleado.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>El
compresor</b>: los más utilizados son:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 91.2pt; mso-add-space: auto; mso-list: l0 level5 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Alternativo o a pistón.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 127.2pt; mso-add-space: auto; mso-list: l0 level6 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Herméticos (bocha negra, el más utilizado).</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 127.2pt; mso-add-space: auto; mso-list: l0 level6 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Semihermeticos.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 127.2pt; mso-add-space: auto; mso-list: l0 level6 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Abiertos.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 91.2pt; mso-add-space: auto; mso-list: l0 level5 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Rotativo</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 91.2pt; mso-add-space: auto; mso-list: l0 level5 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->A espiral.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 91.2pt; mso-add-space: auto; mso-list: l0 level5 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Axihelicoidal o tornillo.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 91.2pt; mso-add-space: auto; mso-list: l0 level5 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Centrífugos.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Condensador</b>:
</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 91.2pt; mso-add-space: auto; mso-list: l0 level5 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Enfriados por aire: Serpentina de cobre con
aletas de aluminio al cual se fuerza pasar aire exterior mediante un ventilador
helicoidal o centrífugo. La descarga de vapor caliente entra por el lado
superior y sale como liquido a la misma temperatura y presión. Su principal
desventaja es la de estar condicionado con la temperatura exterior que es muy
variable y cuando es muy elevada decrece su eficiencia. </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 91.2pt; mso-add-space: auto; mso-list: l0 level5 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Enfriados por agua: son recipientes que entran
en contacto con el agua a temperatura ambiente vinculadas a una torre de
enfriamiento que quita el calor ganado en el contacto pudiendo volver a
utilizarla. Se los puede clasificar en:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 127.2pt; mso-add-space: auto; mso-list: l0 level6 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Tubo en tubo</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 127.2pt; mso-add-space: auto; mso-list: l0 level6 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Casco y tubo o casco y serpentín</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 127.2pt; mso-add-space: auto; mso-list: l0 level6 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Placas</div>
<div class="MsoNormal" style="margin-left: 106.2pt;">
<br /></div>
<div class="MsoNormal" style="margin-left: 106.2pt;">
<br /></div>
<div class="MsoNormal" style="margin-left: 106.2pt;">
Torre de enfriamiento.</div>
<div class="MsoNormal" style="margin-left: 106.2pt;">
Es un dispositivo que recibe el
agua impulsada por una bomba circuladora, desde el condensador del equipo
frigorífico y la distribuye finalmente pulverizada sobre una superficie
plástica laberíntica expuesta a la circulación de aire de un ventilador en
sentido contrario para facilitar su evaporación y enfriamiento, siendo recogida
en una batea e impulsada nuevamente.</div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Dispositivos
de expansión</b>: pueden ser:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 91.2pt; mso-add-space: auto; mso-list: l0 level5 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->tubo capilar o,</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 91.2pt; mso-add-space: auto; mso-list: l0 level5 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->La válvula de expansión termostática, consta de
un diafragma en la que actúa por un lado, la presión de un resorte y por el
otro, la de un bulbo termostático fijado a la línea de succión en la salida del
evaporador. El bulbo se regula de modo que el vapor salga alrededor de 3 a 6°C
y si ese valor prefijado aumenta, se refleja en el bulbo que incrementa la
presión de un lado del diafragma, abriendo la válvula para permitir la
expansión de más cantidad de refrigerante que ingrese al evaporador. </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 91.2pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Evaporador</b>:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 91.2pt; mso-add-space: auto; mso-list: l0 level5 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Expansión DIRECTA: es un serpentín en la zona de
baja presión que produce la reducción de temperatura y extracción de humedad
del aire interior que circula mediante un ventilador centrifugo. El evaporador
puede captar el calor y humedad interior </div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 91.2pt; mso-add-space: auto; mso-list: l0 level5 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--> Expansión
INDIRECTA: mediante agua fría, llamas Maquinas Enfriadoras de Líquidos (M.E.L.)
estas enfrían agua entre 5 a 10 °C en un intercambiador. </div>
<div class="MsoNormal" style="margin-left: 91.2pt;">
Las unidades enfriadoras con
bomba de calor pueden producir agua fría o caliente. Estos equipos logran
eliminar calderas de las sala de maquinas.</div>
<div class="MsoNormal" style="margin-left: 91.2pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">INVERSION DEL CICLO FRIGORIFICO o BOMBA DE CALOR<o:p></o:p></span></b></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;"><br /></span></b></div>
<div class="MsoNormal">
La inversión del ciclo, lo que hace es invertir el sentido
de circulación del refrigerante mediante una válvula inversora de cuatro vías
del tipo corredera, accionada por una solenoide. La válvula inversora conmuta
el ciclo en invierno y el serpentín del evaporador en contacto con el aire
interior pasa a tener gas a 50°C y sale
como un liquido a 50°C entregando al ambiente interior frio, calor latente.</div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /><!--[endif]--></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh1RetfS3i8OchMzo81dOBWf5KcHljL3RVyFkM3_dEkwSuvbaj_0-VFXYKJg6TbDMfKqNBvE1Kn_VneBQuBC6ciFSjA_I20dwhjZdTBG6Uhh5jDgpBr7GboapFGFFDmSW9jcLa7hX6U-ec/s1600/inversion+de+ciclo.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh1RetfS3i8OchMzo81dOBWf5KcHljL3RVyFkM3_dEkwSuvbaj_0-VFXYKJg6TbDMfKqNBvE1Kn_VneBQuBC6ciFSjA_I20dwhjZdTBG6Uhh5jDgpBr7GboapFGFFDmSW9jcLa7hX6U-ec/s1600/inversion+de+ciclo.JPG" height="368" width="400" /></a></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="margin-bottom: 0.0001pt;">
Con solo invertir una
válvula estos sistemas permite pasar de un ciclo a otro, tomando el calor del
aire exterior. Debe restringirse su uso en zonas de baja temperatura, ya que
baja mucho el rendimiento.</div>
<div class="MsoNormal" style="margin-bottom: 0.0001pt;">
<br /></div>
<div class="MsoNormal" style="margin-bottom: 0.0001pt;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj9-5TLW_duTrdgsBQhzkGilN-87TggfWugs1FS8kjmHUhq8efWVDAln7hrcdkQBU-fhu8NtWwuDKWkLOo51QvuxqygmLuz3gIffxvnP28SnKtTrVs5bKXIigx1cadsrjGu8X9SOLL-cnA/s1600/bomba+de+calor.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj9-5TLW_duTrdgsBQhzkGilN-87TggfWugs1FS8kjmHUhq8efWVDAln7hrcdkQBU-fhu8NtWwuDKWkLOo51QvuxqygmLuz3gIffxvnP28SnKtTrVs5bKXIigx1cadsrjGu8X9SOLL-cnA/s1600/bomba+de+calor.JPG" height="262" width="400" /></a></div>
<div class="MsoNormal" style="margin-bottom: 0.0001pt;">
<br /></div>
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-67608849228894643722013-02-15T10:19:00.001-08:002014-09-05T09:38:47.672-07:00CLASIFICACION DE LOS SISTEMAS Y EQUIPAMIENTOS DE AIRE ACONDICIONADO<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiysouOv5klGG5Fq0w59FsqiVhVQ8RWhjV3FPmYS8eXMi1__Gyre9TqrbHryLEpIth1p8qKdUMA_8lxuDDNXLCU7nVoFJjo6t9IA5OTGES8WBY9y-w3ZiAZSriT4dqFmveLdSjk63JSKq4/s1600/tarjetas_originalimprenta_02.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiysouOv5klGG5Fq0w59FsqiVhVQ8RWhjV3FPmYS8eXMi1__Gyre9TqrbHryLEpIth1p8qKdUMA_8lxuDDNXLCU7nVoFJjo6t9IA5OTGES8WBY9y-w3ZiAZSriT4dqFmveLdSjk63JSKq4/s1600/tarjetas_originalimprenta_02.png" height="204" width="320" /></a></div>
<span style="float: left;"><span style="font-family: Arial, Helvetica, sans-serif;">Tel: (03543) 15-553112 Cordoba / (011) 15-5496-1322 Buenos Aires</span></span><br />
<span style="font-family: Arial, Helvetica, sans-serif;"> mail: <a href="mailto:info@nativoarq.com.ar">info@nativoarq.com.ar</a> / diazfernandoariel@yahoo.com.ar </span><br />
<span style="font-family: Arial, Helvetica, sans-serif;">SITIO WEB: http://www.nativoARQ.com.ar </span><br />
<br />
REALIZAMOS PROYECTOS Y OBRAS, SU CONSULTA NO MOLESTA!<br />
<h1>
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">SISTEMAS Y EQUIPAMIENTOS DE AIRE ACONDICIONADO</span></h1>
<div class="MsoNormal">
Las instalaciones de aire acondicionado pueden clasificarse
según los siguientes criterios:</div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">Por su misión<o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><i>Para
confort,</i> creando condiciones atmosféricas que conduzcan al bienestar y a
preservar la salud humana</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><i>Para
procesos industriales</i>, controlando condiciones atmosféricas de modo que
satisfagan los requisitos de su proceso.</div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">Por las estaciones del año en
que actúan / Época de uso<o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><i>Instalaciones
unificadas,</i> tratan el medio interior para calefacción y refrigeración
actuando todo el año. Frio calor simultaneo</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><i>Instalaciones
independientes,</i> son instalaciones totalmente separadas entre sí. Solo frio
o, frio o calor</div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">Por el tipo de equipamiento<o:p></o:p></span></b></div>
<div class="MsoListParagraph" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><i>Expansión
directa,</i> el refrigerante se evapora en el serpentín del evaporador,
enfriando directamente el aire del local. <br />
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgVo8p1x-HFCZRyoXSkglOB-isPDgtkigrJeVxSXoLWO-MyoTimnLNksKvlJovdZOEKx9D2TvFc_4k0yJAuhAW_QQj_GpzcFuH_gzJCh54uUZNMUWMmiqb0Mj_Oi1xIPGTP5YflEYDONsA/s1600/EXPANSION+DIRECTA+CONDENSADA+POR+AIRE.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgVo8p1x-HFCZRyoXSkglOB-isPDgtkigrJeVxSXoLWO-MyoTimnLNksKvlJovdZOEKx9D2TvFc_4k0yJAuhAW_QQj_GpzcFuH_gzJCh54uUZNMUWMmiqb0Mj_Oi1xIPGTP5YflEYDONsA/s1600/EXPANSION+DIRECTA+CONDENSADA+POR+AIRE.JPG" height="296" width="400" /></a></div>
<br />
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhRwDFVwwsoBSb8cH-7afThUQ8-iQlWKiNViINOtNs8PiXrWcjreU7oi_NPYrdEPu4_rpd2swRz4phYHdaUdFxkM03uR2DmhhcNFxhwr1o49QYhvAYYkdl5b_HzNGhOZpNc5_1kSICGQLQ/s1600/EXPANSION+DIRECTA+CONDENSADA+POR+AGUA.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhRwDFVwwsoBSb8cH-7afThUQ8-iQlWKiNViINOtNs8PiXrWcjreU7oi_NPYrdEPu4_rpd2swRz4phYHdaUdFxkM03uR2DmhhcNFxhwr1o49QYhvAYYkdl5b_HzNGhOZpNc5_1kSICGQLQ/s1600/EXPANSION+DIRECTA+CONDENSADA+POR+AGUA.JPG" height="257" width="400" /></a></div>
<br />
<!--[endif]--></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 72.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><i>Expansión
indirecta o de agua fría condensado por aire</i>, el refrigerante enfría el
agua de una maquina enfriadora de líquidos M.E.L., y mediante una bomba, se la
envía por cañerías al serpentín del equipo terminal denominado Fan-Coil, que
enfría el aire del local. Su condensado es por aire.<br />
<br />
<br />
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhAhJNdnCF3tvYm3MUjx5MRpqcYDu3xQkk7sUsR4-Bb7VPhgvXVrqA7hEwwXy90DLQMylvYLGMzGD5y4ugcvKp0_fFJ6m4Cw6FiUGr0lWN-A22Qaokxdmt82bmS3Q2dLkKbD_FMrZtotaQ/s1600/EXPANSION+INDIRECTA+CONDENSADA+POR+AIRE.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em; text-align: center;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhAhJNdnCF3tvYm3MUjx5MRpqcYDu3xQkk7sUsR4-Bb7VPhgvXVrqA7hEwwXy90DLQMylvYLGMzGD5y4ugcvKp0_fFJ6m4Cw6FiUGr0lWN-A22Qaokxdmt82bmS3Q2dLkKbD_FMrZtotaQ/s1600/EXPANSION+INDIRECTA+CONDENSADA+POR+AIRE.JPG" height="258" width="400" /></a></div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br />
<!--[endif]--></div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><i>Expansión
indirecta o de agua fría condensado por agua</i>, el refrigerante enfría el
agua de una maquina enfriadora de líquidos M.E.L., se la envía al fan-coil, que
enfría el aire del local. Su condensado también es por agua, conectando el
sistema intercambiador de calor y a una torre de enfriamiento.<br />
<br />
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhwhsBBTbi_-Xs8j5ng_lInVG6WtiF3nuKj-YkxGSMGwep9rzMBm46bQvgE5ZRIqK4h8tahGO13DoLNNkxG4sHKYt3wrp6qKzCEfUK92wscSINy7hN1f5nKuMs5IDa-1_X8BBd4vExExCQ/s1600/EXPANSION+INDIRECTA+CONDENSADA+POR+AGUA.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhwhsBBTbi_-Xs8j5ng_lInVG6WtiF3nuKj-YkxGSMGwep9rzMBm46bQvgE5ZRIqK4h8tahGO13DoLNNkxG4sHKYt3wrp6qKzCEfUK92wscSINy7hN1f5nKuMs5IDa-1_X8BBd4vExExCQ/s1600/EXPANSION+INDIRECTA+CONDENSADA+POR+AGUA.JPG" height="243" width="400" /></a></div>
<br /></div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<br /></div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<br /></div>
<div class="MsoListParagraphCxSpLast">
<br /></div>
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-82800674906050631312013-02-15T10:13:00.001-08:002014-09-05T09:39:13.431-07:00ACONDICIONAMIENTO DE EXPANSIÓN DIRECTA TODO REFRIGERANTE<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiysouOv5klGG5Fq0w59FsqiVhVQ8RWhjV3FPmYS8eXMi1__Gyre9TqrbHryLEpIth1p8qKdUMA_8lxuDDNXLCU7nVoFJjo6t9IA5OTGES8WBY9y-w3ZiAZSriT4dqFmveLdSjk63JSKq4/s1600/tarjetas_originalimprenta_02.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiysouOv5klGG5Fq0w59FsqiVhVQ8RWhjV3FPmYS8eXMi1__Gyre9TqrbHryLEpIth1p8qKdUMA_8lxuDDNXLCU7nVoFJjo6t9IA5OTGES8WBY9y-w3ZiAZSriT4dqFmveLdSjk63JSKq4/s1600/tarjetas_originalimprenta_02.png" height="204" width="320" /></a></div>
<span style="float: left;"><span style="font-family: Arial, Helvetica, sans-serif;">Tel: (03543) 15-553112 Cordoba / (011) 15-5496-1322 Buenos Aires</span></span><br />
<span style="font-family: Arial, Helvetica, sans-serif;"> mail: <a href="mailto:info@nativoarq.com.ar">info@nativoarq.com.ar</a> / diazfernandoariel@yahoo.com.ar </span><br />
<span style="font-family: Arial, Helvetica, sans-serif;">SITIO WEB: http://www.nativoARQ.com.ar </span><br />
<br />
REALIZAMOS PROYECTOS Y OBRAS, SU CONSULTA NO MOLESTA!<br />
<br />
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">Todo refrigerante <o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l3 level2 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Unitarios<o:p></o:p></b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l3 level2 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Separados<o:p></o:p></b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l1 level3 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; font-size: 12.0pt; line-height: 115%; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt; line-height: normal;"> </span></span><!--[endif]--><b><span style="font-size: 12.0pt; line-height: 115%;">Split<o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l1 level3 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; font-size: 12.0pt; line-height: 115%; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt; line-height: normal;"> </span></span><!--[endif]--><b><span style="font-size: 12.0pt; line-height: 115%;">Multi Split<o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 144.0pt; mso-add-space: auto; mso-list: l1 level4 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; font-size: 12.0pt; line-height: 115%; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt; line-height: normal;"> </span></span><!--[endif]--><b><span style="font-size: 12.0pt; line-height: 115%;">Volumen de refrigerante constante<o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 144.0pt; mso-add-space: auto; mso-list: l1 level4 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; font-size: 12.0pt; line-height: 115%; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt; line-height: normal;"> </span></span><!--[endif]--><b><span style="font-size: 12.0pt; line-height: 115%;">Volumen de refrigerante variable (VRV)<o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l3 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b><span style="text-transform: uppercase;">Unitarios,</span></b><span style="text-transform: uppercase;"> </span> son equipos compactos
autocontenidos de expansión directa, con o sin conductos, con rejillas de
difusión en los propios equipos o mediante plenos de distribución de aire.</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l3 level2 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Individuales</b>,
están empotrados en la pared con todos sus elementos. La unidad condensadora se
coloca del lado exterior y consiste en el compresor, serpentín de condensado y
ventilador helicoidal, por la cual se hace circular el aire exterior, tiene una
persiana donde se puede hacer ingresar una cierta cantidad de aire nuevo. La
unidad evaporadora consta de un serpentín evaporador, ventilador centrifugo,
bandeja de condensado y filtro que se coloca del lado interior.</div>
<div class="MsoNormal" style="margin-left: 70.8pt;">
Su alcance no supera los 5m, con
una capacidad máxima de 6.000 frig/h, monofásicos. Cada equipo acondiciona un
único espacio de pequeñas dimensiones (dormitorio, oficina chica, local). En
desuso.</div>
<div class="MsoNormal" style="margin-left: 70.8pt;">
<br /></div>
<div class="MsoNormal" style="margin-left: 35.4pt; text-indent: 35.4pt;">
<br />
<!--[endif]--></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgiYCseGc1y7mvOJAM69-0pphUtT_RPs0-2SL_B5P6VXeTxKjUfiF1FudoBE5QAIttZnzA7eTwWXyS0JsYetHY-F3P75RHwGux0XANswxrfNHIhqO1JznBYqd2GoXO1zmbaUa0me3YPB4s/s1600/equipo+compacto.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgiYCseGc1y7mvOJAM69-0pphUtT_RPs0-2SL_B5P6VXeTxKjUfiF1FudoBE5QAIttZnzA7eTwWXyS0JsYetHY-F3P75RHwGux0XANswxrfNHIhqO1JznBYqd2GoXO1zmbaUa0me3YPB4s/s1600/equipo+compacto.JPG" height="242" width="400" /></a></div>
<div class="separator" style="clear: both; text-align: center;">
<br /></div>
<div class="MsoNormal" style="margin-left: 35.4pt; text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="margin-left: 35.4pt; text-indent: 35.4pt;">
<br /></div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l0 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b><span style="text-transform: uppercase;">Separados</span>,</b> Este sistema se divide
en dos gabinetes:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l3 level2 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Unidad
evaporadora</b>, contiene un ventilador centrifugo, un filtro de aire, bandeja
de condensado y el serpentín de evaporación. Pueden ser del tipo:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 124.8pt; mso-add-space: auto; mso-list: l2 level2 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Murales, van sujetos a la pared</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 124.8pt; mso-add-space: auto; mso-list: l2 level2 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Cassette, van entre techos suspendidos</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 124.8pt; mso-add-space: auto; mso-list: l2 level2 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->De techo, van sujetos al cielorraso</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 124.8pt; mso-add-space: auto; mso-list: l2 level2 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Consola, van apoyados al piso</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 124.8pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 88.8pt; mso-add-space: auto; mso-list: l2 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Unidad
condensadora</b>, contiene el compresor, el ventilador y el serpentín de
condensación</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 88.8pt; mso-add-space: auto;">
Ambos van unidos por medio de una cañería de cobre para la conducción del
refrigerante y la alimentación eléctrica de de comando. Sale al exterior la
cañería desagüe de condensaciones. El objetivo es separar del interior el
elemento más ruidos que es el compresor. </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 88.8pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 88.8pt; mso-add-space: auto;">
Simple
Split, su longitud de separación entre componentes van de los 10m para equipos
de 2500 frig/h a 20m para 5000 frig/h</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 88.8pt; mso-add-space: auto;">
<br /></div>
<div class="MsoNormal" style="margin-left: 70.8pt;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjJbpnzG6OBNLBBvHxem11fFeuqCq7XagOERZOjrIzlkt13XeU6QlMse0FsvgVRfKsYa3f9IASR1VFDutLT9JyAYAv1BqGk12h7eqlh7nkJpCblT0z2fDgFzZDT0UKmwaUHiKFSa72-lPY/s1600/multi+split.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjJbpnzG6OBNLBBvHxem11fFeuqCq7XagOERZOjrIzlkt13XeU6QlMse0FsvgVRfKsYa3f9IASR1VFDutLT9JyAYAv1BqGk12h7eqlh7nkJpCblT0z2fDgFzZDT0UKmwaUHiKFSa72-lPY/s1600/multi+split.JPG" height="228" width="400" /></a></div>
<div class="MsoNormal" style="margin-left: 70.8pt;">
<br />
<!--[endif]--></div>
<div class="MsoNormal" style="margin-left: 70.8pt;">
<br /></div>
<div class="MsoNormal" style="margin-left: 70.8pt;">
<br /></div>
<div class="MsoNormal" style="margin-left: 70.8pt;">
<br /></div>
<div class="MsoNormal" style="margin-left: 70.8pt;">
Pueden ser:</div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 124.8pt; mso-add-space: auto; mso-list: l2 level2 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><i>Multi
Split, de volumen de refrigerante constante</i>, permite vincular hasta 4
split, no admite grandes longitudes de cañerías por los problemas del retorno
de aceite que desplaza el compresor. La capacidad total del sistema está dada
por la unidad exterior. <!--[endif]--></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 124.8pt; mso-add-space: auto; mso-list: l2 level2 lfo1; text-indent: -18.0pt;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi2NZgkdMJ18B__isvSJQuVa1R2niXl7QdzUXucfB6-ofVLFaXDN94HdLptAN0ZySpkNb21VggkRf9ojiwHxMK01bj8H35E4r99VM6Kprr7r-brvzReyOiD2bDJsF44s426HUZFVSEcd40/s1600/multi+split2.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi2NZgkdMJ18B__isvSJQuVa1R2niXl7QdzUXucfB6-ofVLFaXDN94HdLptAN0ZySpkNb21VggkRf9ojiwHxMK01bj8H35E4r99VM6Kprr7r-brvzReyOiD2bDJsF44s426HUZFVSEcd40/s1600/multi+split2.JPG" height="400" width="356" /></a></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 124.8pt; mso-add-space: auto; mso-list: l2 level2 lfo1; text-indent: -18.0pt;">
<br /></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 124.8pt; mso-add-space: auto; mso-list: l2 level2 lfo1; text-indent: -18.0pt;">
<br /></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 124.8pt; mso-add-space: auto; mso-list: l2 level2 lfo1; text-indent: -18.0pt;">
<br /></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 124.8pt; mso-add-space: auto; mso-list: l2 level2 lfo1; text-indent: -18.0pt;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 124.8pt; mso-add-space: auto; mso-list: l2 level2 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><i>Multi –
Split de volumen de refrigerante variable <b>(VRV),</b></i>
este sistema puede alimentar hasta 32 unidades evaporadoras, vinculadas a una
sola unidad condensadora y </div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 124.8pt; mso-add-space: auto;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjBnvBkHN2MbyY79YA0B-5hINjnwWesSpyr0gztx4xwV5BhmK7mKYkJbSY1FDxB0BTDAEz-0O4Miu6tsSxrCxmnERXufR4VTBnzSiLrMJsPz0yHv1iLucx2lv5uOAUxgeilBqW6eRLRlRE/s1600/vrv.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjBnvBkHN2MbyY79YA0B-5hINjnwWesSpyr0gztx4xwV5BhmK7mKYkJbSY1FDxB0BTDAEz-0O4Miu6tsSxrCxmnERXufR4VTBnzSiLrMJsPz0yHv1iLucx2lv5uOAUxgeilBqW6eRLRlRE/s1600/vrv.JPG" height="223" width="400" /></a></div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 124.8pt; mso-add-space: auto;">
<o:p><br /></o:p></div>
<div class="MsoNormal" style="margin-left: 70.8pt; text-indent: 35.4pt;">
<br />
<!--[endif]--></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 124.8pt; mso-add-space: auto;">
Esta corriente aplicada al motor, le permite regular su velocidad de giro
en función de la demanda, por eso se llaman a estos equipos volumen
refrigerante variable (VRV). El compresor tiene menor desgaste al funcionar
suavemente y al no necesitar parar y arrancar continuamente. Posee separadores
de aceite que eliminan su drenaje por las cañerías y le da más autonomía de
longitud a las unidades evaporadoras, que pueden separarse hasta 100m y
permiten diferencias de altura hasta 50m. </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 124.8pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 124.8pt; mso-add-space: auto;">
Pueden proporcionar frio o calor por inversión de ciclo o bomba de calor,
o bien frio y calor simultáneamente mediante la distribución selectiva de
refrigerante de acuerdo a las necesidades de refrigeración o calefacción de las
unidades. Dicha tarea la asumen unos equipos específicos denominados Cajas de
selección; entre estos y la condensadora van 3 tubos: líquido a 50°C y alta
presión, gas a 50 °C y alta presión y gas a 5°C baja presión.</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 124.8pt; mso-add-space: auto;">
<br /></div>
<div class="MsoNormal">
<br />
<!--[endif]--></div>
<div class="MsoNormal">
<br />
<!--[endif]--></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjfi3l-hq9_nTGc2t4u0-f-8dRHZwU-0TI61RoEhoRYBlL-P5KFMlZl8yrSgVs9yzH4jAXazZVTIIvo5SUo2agGsd_NyqMRJrhDsUUIlpHDPbtJgt3pOOqBG5MRb2WiVlezt5igFQuasGQ/s1600/vrv+frio+calor+simultaneo+3.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjfi3l-hq9_nTGc2t4u0-f-8dRHZwU-0TI61RoEhoRYBlL-P5KFMlZl8yrSgVs9yzH4jAXazZVTIIvo5SUo2agGsd_NyqMRJrhDsUUIlpHDPbtJgt3pOOqBG5MRb2WiVlezt5igFQuasGQ/s1600/vrv+frio+calor+simultaneo+3.JPG" height="131" width="400" /></a></div>
<br />
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi5qnHDrQTYBOMI_cuhVkT5tudyCgehmox2vkxAht9MWuykbqrzKr_SLe0ktVrIRe-3izLzD_kYZbD9ShpDiBIf8yQpmEU_hXhO0IUx7hR0WjLD7EWaq37HkP8tDH_00lP1myND1rtiieg/s1600/vrv+frio+calor+simultaneo.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi5qnHDrQTYBOMI_cuhVkT5tudyCgehmox2vkxAht9MWuykbqrzKr_SLe0ktVrIRe-3izLzD_kYZbD9ShpDiBIf8yQpmEU_hXhO0IUx7hR0WjLD7EWaq37HkP8tDH_00lP1myND1rtiieg/s1600/vrv+frio+calor+simultaneo.JPG" height="131" width="400" /></a></div>
<br />
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEihSOmfbSAXm2x6qnDgRE54mMJkkWRoCMaWo062YrvJh_BVedbpfsiqVrRgDsmJ-euF8JGPaCNWQNgoZdp-c6aYf0Vd_M8NIlOJsNEqYwU93PyeCyTbGDLwmXDyv2H2a7nQRnKj2p7-znM/s1600/vrv+frio+calor+simultaneo+2.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEihSOmfbSAXm2x6qnDgRE54mMJkkWRoCMaWo062YrvJh_BVedbpfsiqVrRgDsmJ-euF8JGPaCNWQNgoZdp-c6aYf0Vd_M8NIlOJsNEqYwU93PyeCyTbGDLwmXDyv2H2a7nQRnKj2p7-znM/s1600/vrv+frio+calor+simultaneo+2.JPG" height="131" width="400" /></a></div>
<div class="MsoNormal">
<br />
<!--[endif]--></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 124.8pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 124.8pt; mso-add-space: auto;">
Las unidades interiores pueden conformar un sistema mixto refrigerante
–aire. Las unidades condensadores exteriores son compactas y moduladas se
fabrican con capacidades de 5, 7.5, 10 y 15 ton. De refrigeración. Los
compresores son del tipo scroll y disponen de un sistema de variación de
frecuencia. </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 124.8pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 124.8pt; mso-add-space: auto;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj87smUtTbSBnEWNBLV63dagXAxz0B3Cvx_udV5gIGRlNxTbebZVGB5_UxzjFutvy6A7R13j5oXtYKmLY3mA4ZwtaWt0_S088A46ccTYZnfzvsSRHvCSIh5uXqHezMzUTP3h7keR3k_750/s1600/vrv2.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj87smUtTbSBnEWNBLV63dagXAxz0B3Cvx_udV5gIGRlNxTbebZVGB5_UxzjFutvy6A7R13j5oXtYKmLY3mA4ZwtaWt0_S088A46ccTYZnfzvsSRHvCSIh5uXqHezMzUTP3h7keR3k_750/s1600/vrv2.JPG" height="400" width="353" /></a></div>
<div class="separator" style="clear: both; text-align: center;">
<br /></div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 124.8pt; mso-add-space: auto;">
<br />
<!--[endif]--></div>
<div class="MsoNormal" style="margin-left: 35.4pt;">
Ventaja:</div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l0 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->que no requieren sala de maquinas, </div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l0 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->no necesita conductos, rejas y difusores. </div>
<div class="MsoNormal" style="margin-left: 35.4pt;">
Desventaja</div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l0 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->es la imposibilidad de tratar el aire nuevo
necesario para la ventilación de los locales, </div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l0 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->no generan sobrepresión</div>
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-13536269789487740772013-02-15T09:53:00.003-08:002014-09-05T09:39:44.582-07:00SISTEMA DE EXPANSION DIRECTA TODO AGUA<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiysouOv5klGG5Fq0w59FsqiVhVQ8RWhjV3FPmYS8eXMi1__Gyre9TqrbHryLEpIth1p8qKdUMA_8lxuDDNXLCU7nVoFJjo6t9IA5OTGES8WBY9y-w3ZiAZSriT4dqFmveLdSjk63JSKq4/s1600/tarjetas_originalimprenta_02.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiysouOv5klGG5Fq0w59FsqiVhVQ8RWhjV3FPmYS8eXMi1__Gyre9TqrbHryLEpIth1p8qKdUMA_8lxuDDNXLCU7nVoFJjo6t9IA5OTGES8WBY9y-w3ZiAZSriT4dqFmveLdSjk63JSKq4/s1600/tarjetas_originalimprenta_02.png" height="204" width="320" /></a></div>
<span style="float: left;"><span style="font-family: Arial, Helvetica, sans-serif;">Tel: (03543) 15-553112 Cordoba / (011) 15-5496-1322 Buenos Aires</span></span><br />
<span style="font-family: Arial, Helvetica, sans-serif;"> mail: <a href="mailto:info@nativoarq.com.ar">info@nativoarq.com.ar</a> / diazfernandoariel@yahoo.com.ar </span><br />
<span style="font-family: Arial, Helvetica, sans-serif;">SITIO WEB: http://www.nativoARQ.com.ar </span><br />
<br />
REALIZAMOS PROYECTOS Y OBRAS, SU CONSULTA NO MOLESTA!<br />
<br />
<div class="MsoNormal">
<b><span style="text-transform: uppercase;">Todo aire<o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l3 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; font-size: 12.0pt; line-height: 115%; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt; line-height: normal;"> </span></span><!--[endif]--><b><span style="font-size: 12.0pt; line-height: 115%;">Equipos Unitarios<o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l3 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; font-size: 12.0pt; line-height: 115%; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt; line-height: normal;">
</span></span><!--[endif]--><b>Wall-Mounted
(para uso de mediana escala)</b><b><span style="font-size: 12.0pt; line-height: 115%;"><o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l3 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; font-size: 12.0pt; line-height: 115%; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt; line-height: normal;">
</span></span><!--[endif]--><b>Roof top (para
uso de gran escala)</b><b><span style="font-size: 12.0pt; line-height: 115%;"><o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l3 level3 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span lang="EN-US" style="font-family: Wingdings; font-size: 12.0pt; line-height: 115%; mso-ansi-language: EN-US; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt; line-height: normal;">
</span></span><!--[endif]--><b><span lang="EN-US">Roof top con V.A.V.</span></b><b><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; mso-ansi-language: EN-US;"><o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l3 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; font-size: 12.0pt; line-height: 115%; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt; line-height: normal;"> </span></span><!--[endif]--><b><span style="font-size: 12.0pt; line-height: 115%;">Equipos separados<o:p></o:p></span></b></div>
<div class="MsoNormal">
Son unidades de
expansión directa, ubicado en una sala de máquina, utilizando como fluido
termodinámico “el aire”, que se distribuye por conductos. Hay unificados que
centralizan el equipamiento facilitando su mantenimiento, y los hay separados. </div>
<div class="MsoNoSpacing">
La ventaja es:</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l0 level1 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Un control más efectivo de humedad del aire de
retorno y del exterior que ingresa como ventilación</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l0 level1 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Un filtrado más eficiente</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l0 level1 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Una distribución más uniforma del aire en los
locales.</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l0 level1 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Generan sobrepresión y ventilación</div>
<div class="MsoNoSpacing">
La desventaja es:</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l0 level1 lfo4; text-indent: -18.0pt;">
<span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;"><br />·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Mayor espacio disponible para el montaje de los
conductos</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l0 level1 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Disponibilidad de una sala de maquinas</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l0 level1 lfo4; text-indent: -18.0pt;">
<div class="separator" style="clear: both; text-align: center;">
</div>
<div class="separator" style="clear: both; text-align: center;">
<a href="http://www.blogger.com/blogger.g?blogID=3273325622788575209" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"></a></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="http://www.blogger.com/blogger.g?blogID=3273325622788575209" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"></a></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="http://www.blogger.com/blogger.g?blogID=3273325622788575209" imageanchor="1" style="display: inline !important; margin-left: 1em; margin-right: 1em; text-indent: 35.4pt;"></a></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="http://www.blogger.com/blogger.g?blogID=3273325622788575209" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"></a></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="http://www.blogger.com/blogger.g?blogID=3273325622788575209" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"></a></div>
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiq3nkwQ25uR5qCTsZAGKBi62kkqvLE62MZV7YrzKqVChsnOTSh5AaUR7AVkkKc7Ghh9HLPTnwa_BlxeB-CStV-i5qvI1sj-H-PlgmZVlSWh8xLbHnjsobGvs2pOFaZ2hRCZ6o-xG7GKkM/s1600/autocontenidos+por+aire.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiq3nkwQ25uR5qCTsZAGKBi62kkqvLE62MZV7YrzKqVChsnOTSh5AaUR7AVkkKc7Ghh9HLPTnwa_BlxeB-CStV-i5qvI1sj-H-PlgmZVlSWh8xLbHnjsobGvs2pOFaZ2hRCZ6o-xG7GKkM/s400/autocontenidos+por+aire.JPG" height="400" width="307" /></a><a href="http://www.blogger.com/blogger.g?blogID=3273325622788575209" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="432" src="file:///C:/Users/Facundo/AppData/Local/Temp/msohtmlclip1/01/clip_image003.jpg" style="cursor: move;" v:shapes="Imagen_x0020_17" width="444" /></a><br />
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Problemas para regular la entrada de aire en
locales con diferentes demandas</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l1 level1 lfo2; text-indent: -18.0pt;">
<span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;"><br />·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Equipos Unitarios,
</b>son equipos compactos autocontenidos, o en una unidad de tratamiento del
aire con expansión directa, ubicados en una sala de maquinas y se lo distribuye
mediante conductos a los locales.</div>
<div class="MsoNormal" style="margin-left: 18.6pt; text-indent: 35.4pt;">
<!--[if gte vml 1]><v:shapetype
id="_x0000_t75" coordsize="21600,21600" o:spt="75" o:preferrelative="t"
path="m@4@5l@4@11@9@11@9@5xe" filled="f" stroked="f">
<v:stroke joinstyle="miter"/>
<v:formulas>
<v:f eqn="if lineDrawn pixelLineWidth 0"/>
<v:f eqn="sum @0 1 0"/>
<v:f eqn="sum 0 0 @1"/>
<v:f eqn="prod @2 1 2"/>
<v:f eqn="prod @3 21600 pixelWidth"/>
<v:f eqn="prod @3 21600 pixelHeight"/>
<v:f eqn="sum @0 0 1"/>
<v:f eqn="prod @6 1 2"/>
<v:f eqn="prod @7 21600 pixelWidth"/>
<v:f eqn="sum @8 21600 0"/>
<v:f eqn="prod @7 21600 pixelHeight"/>
<v:f eqn="sum @10 21600 0"/>
</v:formulas>
<v:path o:extrusionok="f" gradientshapeok="t" o:connecttype="rect"/>
<o:lock v:ext="edit" aspectratio="t"/>
</v:shapetype><v:shape id="Imagen_x0020_18" o:spid="_x0000_i1028" type="#_x0000_t75"
style='width:202.85pt;height:243.55pt;visibility:visible;mso-wrap-style:square'>
<v:imagedata src="file:///C:\Users\Facundo\AppData\Local\Temp\msohtmlclip1\01\clip_image001.jpg"
o:title="autocontenidos por aire"/>
</v:shape><![endif]--><!--[if !vml]--><!--[endif]--></div>
<div class="MsoListParagraph" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo1; text-indent: -18.0pt;">
<br />
<br />
<span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";"><br />o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Wall-Mounted</b>,
son autocontenidos de expansión directa con condensación por aire. Necesita una
entrada y salida de aire para la condensación del refrigerante, por lo que
normalmente se monta sobre una pared exterior, pero puede separarse porque al
contar con un ventilador centrífugo tiene la capacidad de eliminar el aire
caliente de condensación mediante conductos. Diseñados para edificios de
departamentos o pisos de oficinas donde no es posible contar con espacio
exterior para ubicar equipos, puede proveer calefacción mediante la inversión
del ciclo o resistencia eléctrica.</div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal" style="margin-left: 18.6pt; text-indent: 35.4pt;">
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgEDTG6xFNCua5Cqem2JWt6hLADwo6mJE-0xkbNN4ZVO7kS7_eOJN0MZT0W4SHLoFhjRRqdnIHmpQ9hzkaDlghqZ8AI5ZZw_Kmmxf3toEpZRHeuhzE34zowDbyMkWftKqBYBPWhoOByfvY/s1600/sistemas+todo+aire.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgEDTG6xFNCua5Cqem2JWt6hLADwo6mJE-0xkbNN4ZVO7kS7_eOJN0MZT0W4SHLoFhjRRqdnIHmpQ9hzkaDlghqZ8AI5ZZw_Kmmxf3toEpZRHeuhzE34zowDbyMkWftKqBYBPWhoOByfvY/s400/sistemas+todo+aire.JPG" height="388" width="400" /></a></div>
<b><br /><!--[endif]--></b></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 72.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Roof top</b>,
son compactos, autocontenidos de expansión directa por aire, admiten la
instalación de conductos de distribución, tiene descarga vertical hacia abajo
y horizontal. Se los utiliza para
aplicaciones comerciales y residenciales. Para calefacción se los utiliza con
bomba de calor, pero también se fabrican con intercambiador de calor a gas
natural o resistencias eléctricas.</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo1; text-indent: -18.0pt;">
<br /></div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo1; text-indent: -18.0pt;">
<br /></div>
<div class="MsoNormal">
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi56VOLl8l1yQ7XKj3X0x3kPREr7JiZ_9Q0w-jOVzTHS1vt6JXkoGoYajwLs2U7TL7PJewf2O1TwI8YtH4rgmdy_NxY_3d8uvtllh55dLoK8HHQXAFM9_frIFzjJedCwjCpmgQR8C_c1_s/s1600/roof+top2.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi56VOLl8l1yQ7XKj3X0x3kPREr7JiZ_9Q0w-jOVzTHS1vt6JXkoGoYajwLs2U7TL7PJewf2O1TwI8YtH4rgmdy_NxY_3d8uvtllh55dLoK8HHQXAFM9_frIFzjJedCwjCpmgQR8C_c1_s/s400/roof+top2.JPG" height="330" width="400" /></a></div>
<br />
<!--[endif]--></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l2 level3 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Volumen
de aire Variable (VAV).</b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 55.2pt; mso-add-space: auto; text-indent: 34.8pt;">
Puede ser zonal, individual o central.</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 90.0pt; mso-add-space: auto; text-indent: 1.9pt;">
Sistema de control aplicable a las instalaciones con
conductos que permite variar el caudal del aire impulsado manteniendo constante
para todos los locales su temperatura (así como su grado de humedad y su tasa
de aire exterior). Son persianas comandadas por termostatos que se abren o
cierran a demanda, tienen una apertura
mínima del 15%, asegurando la renovación de aireen cada local. El cierre aunque
parcial genera una sobrepresión inadmisible la cual es disipada por un bay-pass
que descarga el aire de mando a la cámara de mezcla a través de persianas
barométricas.</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 90.0pt; mso-add-space: auto; text-indent: 1.9pt;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgPT3sIQ5LXRuBuX_O0sbuKzbZNaqTwdVKKtK47B5db7B9-SmunO1fz75-n3kajZsQhhx6SLHu2HvFooJzrfeCPimIEO593_EJAlXfgnkuM9kyOdyiWovKxoFYc4VOmbnFb45Vh05o64p4/s1600/roof+top.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgPT3sIQ5LXRuBuX_O0sbuKzbZNaqTwdVKKtK47B5db7B9-SmunO1fz75-n3kajZsQhhx6SLHu2HvFooJzrfeCPimIEO593_EJAlXfgnkuM9kyOdyiWovKxoFYc4VOmbnFb45Vh05o64p4/s400/roof+top.JPG" height="400" width="367" /></a></div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 90.0pt; mso-add-space: auto; text-indent: 1.9pt;">
<br /></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 71.4pt; mso-add-space: auto; text-indent: 34.8pt;">
<br />
<!--[endif]--></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 71.4pt; mso-add-space: auto; text-indent: 34.8pt;">
<br /></div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l1 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b> Equipos separados</b>, está compuesto por un
equipo autocontenidos interior que contiene el compresor, evaporador y
ventilador, el que es vinculado mediante cañerías de refrigerante con un
gabinete en el exterior que contiene el ventilador y el serpentín de
condensación. El equipo se lo puede colocar en el mismo local con pleno de
distribución, pero generalmente, se emplaza en una sala de maquinas separada
distribuyendo el aire por conducto.</div>
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com1tag:blogger.com,1999:blog-3273325622788575209.post-41567036365629826132013-02-15T09:51:00.000-08:002014-09-05T09:37:49.844-07:00SISTEMAS DE EXPANSIÓN INDIRECTA TODO AGUA<br />
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiysouOv5klGG5Fq0w59FsqiVhVQ8RWhjV3FPmYS8eXMi1__Gyre9TqrbHryLEpIth1p8qKdUMA_8lxuDDNXLCU7nVoFJjo6t9IA5OTGES8WBY9y-w3ZiAZSriT4dqFmveLdSjk63JSKq4/s1600/tarjetas_originalimprenta_02.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiysouOv5klGG5Fq0w59FsqiVhVQ8RWhjV3FPmYS8eXMi1__Gyre9TqrbHryLEpIth1p8qKdUMA_8lxuDDNXLCU7nVoFJjo6t9IA5OTGES8WBY9y-w3ZiAZSriT4dqFmveLdSjk63JSKq4/s1600/tarjetas_originalimprenta_02.png" height="204" width="320" /></a></div>
<span style="float: left;"><span style="font-family: Arial, Helvetica, sans-serif;"><br /></span></span><span style="float: left;"><span style="font-family: Arial, Helvetica, sans-serif;">Tel: (03543) 15-553112 Cordoba / (011) 15-5496-1322 Buenos Aires</span></span><br />
<span style="font-family: Arial, Helvetica, sans-serif;"> mail: <a href="mailto:info@nativoarq.com.ar">info@nativoarq.com.ar</a> / diazfernandoariel@yahoo.com.ar </span><br />
<span style="font-family: Arial, Helvetica, sans-serif;">SITIO WEB: http://www.nativoARQ.com.ar </span><br />
<br />
REALIZAMOS PROYECTOS Y OBRAS, SU CONSULTA NO MOLESTA!<br />
<div class="MsoNormal">
<b><span style="text-transform: uppercase;">Todo agua<o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l2 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; font-size: 12.0pt; line-height: 115%; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt; line-height: normal;"> </span></span><!--[endif]--><b><span style="text-transform: uppercase;">maquinas
enfriadora de liquidos “m.e.l.” (</span>Maquinas enfriadoras de liquidos<span style="text-transform: uppercase;">) o “chiller”</span></b><b><span style="font-size: 12.0pt; line-height: 115%;"><o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l0 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span lang="EN-US" style="font-family: "Courier New"; font-size: 12.0pt; line-height: 115%; mso-ansi-language: EN-US; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt; line-height: normal;">
</span></span><!--[endif]--><b>Condensadas
por aire</b><b><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; mso-ansi-language: EN-US;"><o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l0 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span lang="EN-US" style="font-family: "Courier New"; font-size: 12.0pt; line-height: 115%; mso-ansi-language: EN-US; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt; line-height: normal;">
</span></span><!--[endif]--><b>Condensadas
por agua</b><b><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; mso-ansi-language: EN-US;"><o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l0 level3 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; font-size: 12.0pt; line-height: 115%; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt; line-height: normal;"> </span></span><!--[endif]--><b>Equipos enfriados por agua con bomba de
calor (WSHP).</b><b><span style="font-size: 12.0pt; line-height: 115%;"><o:p></o:p></span></b></div>
<div class="MsoNormal">
Son equipos separados
de expansión indirecta, que utilizan como fluido termodinámico “el agua”
dotados con una unidad enfriadora de agua que transporta el fluido frio a
terminales denominadas fan-coil. Por ellos circulan agua fría y/o caliente, desde
el mismo sistema mediante la inversión del ciclo o a través de un serpentín
secundario separado alimentado por calderas.</div>
<div class="MsoNormal" style="margin-left: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="margin-left: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="margin-left: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="margin-left: 35.4pt;">
Unidad enfriadora de agua:</div>
<div class="MsoNormal" style="margin-left: 35.4pt;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiq9fUnU0L1btI4IBmjSksRQlvgzfAPUpET1JbpHp2TTA680FBxLHdd9mqPNIphhgkmjpBsQevLchNzf-yCBcCrh6fYHj0aUUBVDbLxUJ3TWnPn_MX6jzAtW25tlVfIlRt0Odu-9PiQlRY/s1600/enfriadora+de+liquidos+centrifuga.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiq9fUnU0L1btI4IBmjSksRQlvgzfAPUpET1JbpHp2TTA680FBxLHdd9mqPNIphhgkmjpBsQevLchNzf-yCBcCrh6fYHj0aUUBVDbLxUJ3TWnPn_MX6jzAtW25tlVfIlRt0Odu-9PiQlRY/s320/enfriadora+de+liquidos+centrifuga.JPG" height="209" width="320" /></a></div>
<div class="separator" style="clear: both; text-align: center;">
<br /></div>
<div class="MsoNormal" style="margin-left: 35.4pt; text-indent: 35.4pt;">
<br />
<!--[endif]--></div>
<div class="MsoNormal" style="margin-left: 35.4pt;">
Cada unidad terminal fan –coil
está constituida por un gabinete que contiene la toma de aire, filtro,
serpentín y ventiladores centrífugos, que son de doble entrada montados sobre
un eje común a un motor eléctrico que distribuye el aire a través de una reja
horizontal o vertical sin utilizar conductos, por eso se denomina sistema todo
agua.</div>
<div class="MsoNormal" style="margin-left: 35.4pt;">
Estos equipos permiten introducir
cierta cantidad de aire exterior a través de una pequeña abertura en la pared
hacia un pleno de mezcla en la parte inferior, este aire se mescla con el aire
de retorno, pasa por un filtro y se enfría o calienta para ser inyectada al
ambiente.</div>
<div class="MsoNormal" style="margin-left: 35.4pt;">
Pueden ser:</div>
<div class="MsoListParagraph" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l1 level2 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Condensados
por aire, </b>son equipos condensadores para ubicar en el exterior<b><o:p></o:p></b></div>
<div class="MsoListParagraph" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l1 level2 lfo1; text-indent: -18.0pt;">
<br /></div>
<div class="MsoNormal" style="margin-left: 18.6pt; text-indent: 35.4pt;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj7dlvOf2O9-rApCO6vzoFkwt-vy_93lQGETbwSgcKZ8aijhU8YVhjRwLNfJMdOE6IXgCpawdYCSSL3BrpUVK8eNyGIzA64CrzW04SeRuEdt7FVjgJzNL0C3JBCm5WqQ_c4VWowMt6ScLg/s1600/mel+condensada+por+aire2.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj7dlvOf2O9-rApCO6vzoFkwt-vy_93lQGETbwSgcKZ8aijhU8YVhjRwLNfJMdOE6IXgCpawdYCSSL3BrpUVK8eNyGIzA64CrzW04SeRuEdt7FVjgJzNL0C3JBCm5WqQ_c4VWowMt6ScLg/s400/mel+condensada+por+aire2.JPG" height="297" width="400" /></a></div>
<div class="MsoNormal" style="margin-left: 18.6pt; text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<b><br /></b></div>
<div class="MsoListParagraph" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l1 level2 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Condensadores
enfriadores por agua, con torre de enfriamiento de flujos paralelos</b>, la
terminal condensadora y la maquina enfriadora de líquidos son equipos aptos
para ubicar en el interior. El calor extraído por el agua del condensador se lo
envía mediante una bomba recirculándola a una torre de enfriamiento exterior
donde se le extrae el calor. La calefacción se realiza con agua caliente de una
caldera o resistencias eléctricas.</div>
<div class="MsoNormal" style="margin-left: 70.8pt; text-indent: 35.4pt;">
<br />
<!--[endif]--></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEia_TEfqPsinwCs-PJ7fOziiSQzG9TnNQu886eoZKkcWxwWDrdfgk6h5VidQ92bR9UdJ7gy7YIig5_nbkwF5gPqzJqhWi-iO0qHuf-ZkRlBygfogbpWO22yWPjSs9QZ7qiLlZs8bzlAIT8/s1600/torre+de+enfriamiento+de+flujos+paralelos.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEia_TEfqPsinwCs-PJ7fOziiSQzG9TnNQu886eoZKkcWxwWDrdfgk6h5VidQ92bR9UdJ7gy7YIig5_nbkwF5gPqzJqhWi-iO0qHuf-ZkRlBygfogbpWO22yWPjSs9QZ7qiLlZs8bzlAIT8/s320/torre+de+enfriamiento+de+flujos+paralelos.JPG" height="269" width="320" /></a></div>
<div class="separator" style="clear: both; text-align: center;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgXe9ZvjAGg5wiZGdjUuqlGYhIbMhyxcVHjfwelIBde0S_UjxeYhBo8JzKUc33JRPsPQSvjItExLigsqcCJa7ac-4keAPW5JaUCuLm-HxwR1C8rjgrKSBpEteC9iwDvp0mGh-6aWCTqnyE/s1600/TORRES+DE+ENFRIAMIENTO.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgXe9ZvjAGg5wiZGdjUuqlGYhIbMhyxcVHjfwelIBde0S_UjxeYhBo8JzKUc33JRPsPQSvjItExLigsqcCJa7ac-4keAPW5JaUCuLm-HxwR1C8rjgrKSBpEteC9iwDvp0mGh-6aWCTqnyE/s1600/TORRES+DE+ENFRIAMIENTO.JPG" height="400" width="245" /></a></div>
<div class="separator" style="clear: both; text-align: center;">
<br /></div>
<div class="MsoNormal" style="margin-left: 70.8pt; text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="margin-left: 70.8pt; text-indent: 35.4pt;">
<br /></div>
<div class="MsoListParagraph" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l2 level3 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Dentro de
esta familia existe la variable de Equipos enfriados por agua con bomba de calor
(WSHP).</b> Estos equipos son vinculados para la condensación mediante dos
cañerías de distribución, con una torre de enfriamiento en circuito cerrado
para la refrigeración o con una caldera de agua caliente como refuerzo del
ciclo de calefacción. Las unidades se ubican de modo de servir las distintas
zonas del edificio, una zona puede requerir refrigeración en temporada
templada, por lo que el calor de condensación cedido por estas unidades al agua
es desplazado a las zonas perimetrales que necesitan calefacción y al
transferir el calor del mismo edificio da como resultado un ahorro energético.</div>
<div class="MsoListParagraph" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l2 level3 lfo2; text-indent: -18.0pt;">
<br /></div>
<div class="MsoNormal" style="margin-left: 35.4pt;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjnxjATJlnoyRIesQfmY1e4ccnh_HQIKoZtKslLpCCJSoGgzYwRoK_PLkrO3UnFN_w2xuuuUo81a7I0K3Bd6JxrAzt3Qc6WCUh1PrqDz7NeO2J9y7NJlyocqdifipsYpxOUdRXGzYYIXww/s1600/mel+condensada+por+agua+mas+fan+coil.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjnxjATJlnoyRIesQfmY1e4ccnh_HQIKoZtKslLpCCJSoGgzYwRoK_PLkrO3UnFN_w2xuuuUo81a7I0K3Bd6JxrAzt3Qc6WCUh1PrqDz7NeO2J9y7NJlyocqdifipsYpxOUdRXGzYYIXww/s400/mel+condensada+por+agua+mas+fan+coil.JPG" height="295" width="400" /></a></div>
<div class="MsoNormal" style="margin-left: 35.4pt; text-indent: 35.4pt;">
<br />
<!--[endif]--></div>
<div class="MsoNormal" style="margin-left: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="margin-left: 35.4pt;">
En instalaciones grandes se puede
regular el caudal de agua suministrando, mediante el empleo de válvulas de tres
vías modulantes, adecuando de esa manera su capacidad a las cargas parciales.</div>
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-47930109526739540792013-02-15T09:44:00.001-08:002013-02-15T09:44:42.389-08:00DISTRIBUCIÓN DEL AGUA FRÍA Y CALIENTE A LOS FAN-COIL<br />
<div class="MsoListParagraph">
<b><span style="text-transform: uppercase;">distribución del agua fría y caliente a los
fan-coil <o:p></o:p></span></b></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
La distribución del agua fría y
caliente a los fan-coil se puede realizar mediante:</div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoListParagraph" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Dos tuberías, es la más económica y se utiliza
en edificios residenciales. Consiste en un caño de alimentación y otro de
retorno a un serpentín único en cada fan-coil que en verano recibe agua fría y
en invierno agua caliente de una caldera o de la misma unidad enfriadora
actuando como bomba de calor. Esta instalación no es apta en épocas intermedias
donde pueden existir zonas que requieran frio o calor simultáneamente.</div>
<div class="MsoListParagraph" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjZwTLBHfgvLT-e2rs9K6yKe6FsBegKZvpbykWVw9DD8WFxhGE6kGjhHrHuWFgYHidR5kI8pGvDgT_ZhZwwBL0NDNKBWSa2clmLtCMNIe36PY4yU8i93hMmzrfb2gCblDBKlEwEPyjoKNo/s1600/INST+DE+2+CA%C3%91OS.jpeg.jpeg.jpeg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="400" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjZwTLBHfgvLT-e2rs9K6yKe6FsBegKZvpbykWVw9DD8WFxhGE6kGjhHrHuWFgYHidR5kI8pGvDgT_ZhZwwBL0NDNKBWSa2clmLtCMNIe36PY4yU8i93hMmzrfb2gCblDBKlEwEPyjoKNo/s400/INST+DE+2+CA%C3%91OS.jpeg.jpeg.jpeg" width="290" /></a></div>
<div class="separator" style="clear: both; text-align: center;">
<br /></div>
<div class="MsoNormal">
<br /><!--[endif]--></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Tres tuberías, llega a un único serpentín una
alimentación de agua fría, otra de agua caliente y sale un único retorno. Una
válvula automática de tres vias abre el paso del agua de una u otra, siendo el
retorno común entre amabas. Esta instalación ha caído en desuso porque existe
el peligro de recirculaciones de agua caliente por las enfriadoras o frías por
la caldera.<!--[endif]--></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgIXCEj9mFjGLuJPsDzSMoJ2kkamOG_YGMD6uvUmvWcyOZo0tUqjsVHTPyqrpGakK7u1RFFg5XiGchem0KWBOxtci6ODlCuHKzduDXs1E4TBbyw_D8v8EneaiQf-8b1XsVAspQvkwPnHbg/s1600/INST+DE+3+CA%C3%91OS.jpeg.jpeg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="400" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgIXCEj9mFjGLuJPsDzSMoJ2kkamOG_YGMD6uvUmvWcyOZo0tUqjsVHTPyqrpGakK7u1RFFg5XiGchem0KWBOxtci6ODlCuHKzduDXs1E4TBbyw_D8v8EneaiQf-8b1XsVAspQvkwPnHbg/s400/INST+DE+3+CA%C3%91OS.jpeg.jpeg" width="290" /></a></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<br /></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<br /></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 0cm; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: 0cm;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Cuatros tuberías, funciona todo el año. Cada
fan-coil tiene dos baterías o una separada en dos partes, uno para
refrigeración y otro para calefacción y mediante válvulas automáticas se regula
la secuencia de funcionamiento según la necesidad.<!--[endif]--></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 0cm; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: 0cm;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjYk2TxOyGUpQMCfFCW_eSmlwlQU5T0lX2gD6c8ri8YtcnJnlMvqTUnSL818yt_Q9r5xYX0qjwtyUE0s-h-DHHS_wmRjPDqnYCrGlW5vwe-YGsSFSN3ulBD3oF2WVjUcXmvQ1lJs5TzaAc/s1600/INST+DE+4+CA%C3%91OS.jpeg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="400" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjYk2TxOyGUpQMCfFCW_eSmlwlQU5T0lX2gD6c8ri8YtcnJnlMvqTUnSL818yt_Q9r5xYX0qjwtyUE0s-h-DHHS_wmRjPDqnYCrGlW5vwe-YGsSFSN3ulBD3oF2WVjUcXmvQ1lJs5TzaAc/s400/INST+DE+4+CA%C3%91OS.jpeg" width="290" /></a></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 0cm; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: 0cm;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj1hI_Iaf68OVyx1qGSu9n4yH6XOeQUI0fN5GScz6AwFz1ioMxNTPZgCZFNa97xGSXF4uB1KExgFx5nlRGgQ2mVdrL_o1s7xRNqWeBycbYYPlHPQAe40YmpHMbZ19WKcOKrlY3wEQ2WNK4/s1600/ESQUEMA+exp+ind.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="400" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj1hI_Iaf68OVyx1qGSu9n4yH6XOeQUI0fN5GScz6AwFz1ioMxNTPZgCZFNa97xGSXF4uB1KExgFx5nlRGgQ2mVdrL_o1s7xRNqWeBycbYYPlHPQAe40YmpHMbZ19WKcOKrlY3wEQ2WNK4/s400/ESQUEMA+exp+ind.jpg" width="320" /></a></div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 0cm; mso-add-space: auto;">
<br /><!--[endif]--></div>
<div class="MsoNormal" style="margin-left: 35.4pt;">
Todas las cañerías deben aislarse
para evitar pérdidas de calor o frio. En todos los casos hay que prever la
eliminación a la red de desagüe cloacal, sifón mediante, el agua de condensado.
Las terminales pueden ser tipo consola, murales o casetes.</div>
<div class="MsoNormal" style="margin-left: 18.0pt; text-indent: 17.4pt;">
Las ventajas
del sistema son:</div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 74.1pt; mso-add-space: auto; mso-list: l1 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->que no emplea conductos de distribución que requieren
mucho espacio, </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 74.1pt; mso-add-space: auto; mso-list: l1 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->la bomba de agua consume menos energía que un
ventilador de aire, </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 74.1pt; mso-add-space: auto; mso-list: l1 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->se puede efectuar regulación automática o manual
de la temperatura en forma independiente en cada terminal por ambiente</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 74.1pt; mso-add-space: auto; mso-list: l1 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->la circulación de aire es independiente de cada
local por lo que es útil para hoteles u hospitales.</div>
<div class="MsoNormal" style="margin-left: 18.0pt; text-indent: 17.4pt;">
Las
desventajas son:</div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 74.1pt; mso-add-space: auto; mso-list: l1 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->En una instalación de gran envergadura, el
edificio necesita una gran cantidad de aberturas para las tomas de aire
exterior, que es limitada y pueden produjese en invierno o en edificios altos
la entrada de agua de lluvia.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 74.1pt; mso-add-space: auto; mso-list: l1 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Al haber tantas unidades individuales se
multiplica el mantenimiento de filtros, ventiladores.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 74.1pt; mso-add-space: auto; mso-list: l1 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Se genera mucha cantidad de agua de condensado
en cada unidad ya que ella se produce el tratamiento la mezcla del aire
exterior.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 74.1pt; mso-add-space: auto; mso-list: l1 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Su alcance es limitado, no más de 5 mts.</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 74.1pt; mso-add-space: auto; mso-list: l1 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->No generan sobrepresión</div>
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-61063938918323926742013-02-15T09:38:00.002-08:002013-02-15T09:39:18.685-08:00SISTEMA MIXTO DE ACONDICIONAMIENTO DE AIRE ACONDICIONADO<br />
<div class="MsoNormal">
<b><span style="font-size: 12.0pt; line-height: 115%;">Sistemas mixtos</span></b>, son
combinaciones que toman de cada sistema sus potencialidades y aumenta la
eficiencia de la instalación<br />
<br />
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">SISTEMA MIXTO AGUA – AIRE, <o:p></o:p></span></b></div>
<div class="MsoNormal">
Consiste en el empleo de fan-coil individuales sin toma de
aire exterior, distribuyéndose el aire nuevo de ventilación en forma directa a
los locales, mediante conductos provenientes de un equipo fan-coil central,
donde se efectúa su acondicionamiento, de esta manera las zonas periféricas son
alimentadas con fan-coil individuales sin toma de aire y la zona central es
abastecida por la unidad de tratamiento de aire que genera la ventilación y
sobrepresión necesaria. Con este sistema se mejora la eficiencia de filtrado,
se eliminan las entradas de aire por cada fan-coil y se efectúa la
deshumectación del aire en la unidad central, limitando a los equipos fan coil
solo al aire interior, eliminando así menos cantidad de agua de condensado.</div>
<div class="MsoNormal">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgfUVHs7Uki7YuspZzxp73XKl367qW_dBGZme4qUsNsQpHQdrCKP_7OJ7JBYIAzuThdozQwvlw68taHLMFkdr90sM82yuyovssnngJlDAPwEwq47n4NmvpRaEN-ZEzS8iuOz_n-BWULCZs/s1600/mel+condensada+por+aire.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="270" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgfUVHs7Uki7YuspZzxp73XKl367qW_dBGZme4qUsNsQpHQdrCKP_7OJ7JBYIAzuThdozQwvlw68taHLMFkdr90sM82yuyovssnngJlDAPwEwq47n4NmvpRaEN-ZEzS8iuOz_n-BWULCZs/s400/mel+condensada+por+aire.JPG" width="400" /></a></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br />
<!--[endif]--></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEixpaLNRn2Kb4AHre7Q94GJXVkKBcmGnhjOOeHNgBbhD53jmQ5rv4-9x6y4gdY3BCdVyklO89GZ94Nhqe5scN8WWopk9JBniQ1_0WiFeSB3AirJO8TFydl9BnSBccTEQ49p_-Q6Cifq3YQ/s1600/SISTEMA+MIXTO+AGUA+AIRE.jpeg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="640" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEixpaLNRn2Kb4AHre7Q94GJXVkKBcmGnhjOOeHNgBbhD53jmQ5rv4-9x6y4gdY3BCdVyklO89GZ94Nhqe5scN8WWopk9JBniQ1_0WiFeSB3AirJO8TFydl9BnSBccTEQ49p_-Q6Cifq3YQ/s640/SISTEMA+MIXTO+AGUA+AIRE.jpeg" width="408" /></a></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;"> </span></b><b style="text-indent: 35.4pt;"><span style="text-transform: uppercase;"> </span></b></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">SISTEMA MIXTO REFRIGERANTE – AIRE<o:p></o:p></span></b></div>
<div class="MsoNormal">
Esta solución también es posible con unidades evaporadoras
multi split combinadas con manejadoras de aire de expansión directa,
constituyendo así un sistema refrigerante –aire, que puede ser de volumen de
refrigerante constante o variable si son muchas unidades interiores.</div>
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-74707494109528682402013-02-15T09:32:00.000-08:002013-02-15T09:33:38.859-08:00FORMA DE DISTRIBUCIÓN DEL AIRE EN LOS LOCALES<br />
<div class="MsoNormal" style="margin-left: 18.0pt;">
<b><span style="text-transform: uppercase;">FORMA DE DISTRIBUCIÓN DEL AIRE
EN LOS LOCALES<o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l6 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Por
mezclado</b>, se inyecta aire con rejas velocidades más altas que las toleradas
en la zona de ocupación en el extremos superior del local, a medida que este
aire primario ingresa arrastra y se mezcla por inducción el aire del ambiente,
denominado aire secundario, incrementando su volumen y modificando su
temperatura y humedad, por ultimo llega a la zona de ocupación, donde es tomado
por el conducto de retorno enviado a la cámara de mezcla y vuelto a
acondicionar.</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l6 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Por
desplazamiento</b>, se inyecta aire con difusores colocados en el cielorraso
produciendo el efecto denominado <b><i>coanda</i></b>, hace que el aire se adhiera
a lo largo del techo, generando una envolvente plana que reduce la caída y
aumenta el alcance o propagación del flujo primario.</div>
<div class="MsoNormal">
Como norma básica de proyecto, debe ubicarse la reja de
retorno en un punto que capte el aire en las condiciones de diseño del
ambiente, sin que sea influido por corrientes de aire primario, ni por aire
exterior, es preferible que se ubiquen en la parte inferior u opuesta a las
rejas o difusores.</div>
<div class="MsoListParagraph" style="mso-list: l2 level1 lfo8; text-indent: -18.0pt;">
<!--[if !supportLists]-->1.<span style="font-size: 7pt;">
</span><!--[endif]-->¿Cuánto es el aire que debemos transportar?:</div>
<div class="MsoNormal">
Depende del caudal circundante, el Caudal de aire frio:</div>
<div class="MsoNormal">
C= Qsi / 170</div>
<div class="MsoListParagraphCxSpFirst">
Donde:</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l8 level1 lfo7; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Qsi: ganancia de calor sensible (Kcal / h)</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l8 level1 lfo7; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->170: factor que surge de las diferencias de
temperaturas entre el aire de retorno y de alimentación, el peso y calor
especifico del aire</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l8 level1 lfo7; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->C: caudal de aire circulante (m3 / min)</div>
<div class="MsoListParagraphCxSpMiddle">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo8; text-indent: -18.0pt;">
<!--[if !supportLists]-->2.<span style="font-size: 7pt;">
</span><!--[endif]-->¿Cuál es la velocidad conveniente a la que
debemos transportar el aire?</div>
<div class="MsoListParagraphCxSpMiddle">
Se pueden establecer la velocidad máxima
conveniente, de acuerdo al Destino del local y Tipo de aire (frio / caliente),
para aire frio:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l5 level2 lfo5; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Locales industriales: 500 m/min</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l5 level2 lfo5; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Oficinas de personal: 300 a 450 m/min</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l5 level2 lfo5; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Viviendas:
300 m / min<o:p></o:p></b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l2 level1 lfo8; text-indent: -18.0pt;">
<!--[if !supportLists]-->3.<span style="font-size: 7pt;">
</span><!--[endif]-->¿A dónde debemos transportar el aire?</div>
<div class="MsoNormal">
A todos aquellos locales que deseamos acondicionar. </div>
<div class="MsoNormal">
<br /></div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l3 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Simple
zona,</b> es cuando se alimentan varios locales mediante un único conducto,
esta es aceptable para el caso que los locales tengan cargas térmicas
similares.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
LOS CONDUCTOS PUEDEN DISPONERSE</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l3 level2 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Enfrentados</b></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgqX_ceG2lcBJnpNyJq7UHA_Zn0SH9U3jwo2WOQIyQqd5HslQpImB2vGHrj_g9DWLgZgMHz4w65dQdduA4OgIA8ND5n7QuW3MKO_-STlv8I-H-8Y8f_KScBmc_ua29AiLZ-aw88N5DAy5g/s1600/ENFRENTADOS.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="162" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgqX_ceG2lcBJnpNyJq7UHA_Zn0SH9U3jwo2WOQIyQqd5HslQpImB2vGHrj_g9DWLgZgMHz4w65dQdduA4OgIA8ND5n7QuW3MKO_-STlv8I-H-8Y8f_KScBmc_ua29AiLZ-aw88N5DAy5g/s320/ENFRENTADOS.JPG" width="320" /></a></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<b><br /><!--[endif]--></b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<span style="font-family: "Courier New"; text-indent: -18pt;">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><b style="text-indent: -18pt;">En espina</b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l3 level2 lfo1; text-indent: -18.0pt;">
<b><br /></b></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjSzqF_0hvWuhNe-QrdqbuEpU3LGwF8QDeyODkMvZ4pnrkAoLEG9Yq2y7pkXFeG0gtmJ7ZehIAmZRgVuACA9C_qvrtQtZFBn1ZJDSSCwUZQWycEhwrI0bz74LCKSTXV7TiJH3y0tNnbKtQ/s1600/ESPINA.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="162" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjSzqF_0hvWuhNe-QrdqbuEpU3LGwF8QDeyODkMvZ4pnrkAoLEG9Yq2y7pkXFeG0gtmJ7ZehIAmZRgVuACA9C_qvrtQtZFBn1ZJDSSCwUZQWycEhwrI0bz74LCKSTXV7TiJH3y0tNnbKtQ/s320/ESPINA.JPG" width="320" /></a></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<b><br /><!--[endif]--></b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<span style="font-family: "Courier New"; text-indent: -18pt;">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><b style="text-indent: -18pt;">Peine</b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l3 level2 lfo1; text-indent: -18.0pt;">
<b><br /></b></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhwJ2L89rLwRFO4zGnUsSYLOwo_gUmsYrZijJgOXNIW9D2RM_oPdieOLwOfwiXBfXh-CCq4pnAW-cTQqSdwSd7UbpnzjV3y7KcflmQPUzzzxIsCffdDxwTKIsn0vpZk1wcKOquwgz53QGg/s1600/PEINE.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="164" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhwJ2L89rLwRFO4zGnUsSYLOwo_gUmsYrZijJgOXNIW9D2RM_oPdieOLwOfwiXBfXh-CCq4pnAW-cTQqSdwSd7UbpnzjV3y7KcflmQPUzzzxIsCffdDxwTKIsn0vpZk1wcKOquwgz53QGg/s320/PEINE.JPG" width="320" /></a></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<b><br /><!--[endif]--></b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<b><br /></b></div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l3 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Multi
zona</b>, generalmente los edificios deben dividirse en zonas de
acondicionamiento teniendo en cuenta:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l3 level2 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->La orientación</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l3 level2 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->El horario de ocupación</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l3 level2 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Diversidad de cargas</div>
<div class="MsoNormal" style="margin-left: 35.4pt;">
Para ello se utilizan dos
métodos:</div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 71.4pt; mso-add-space: auto; mso-list: l7 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->De recalentamiento, mediante una resistencia
térmica se calienta el aire frio para aquellos locales que hayan llegado al
confort, este sistema genera un gasto excesivo de energía.</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 71.4pt; mso-add-space: auto; mso-list: l7 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Mezcla de aire frio con templado, la distribución
del aire por doble conducto consiste en un conducto que transporta aire frio y
otro aire templado y mediante una caja mezcladora ubicada en el local a servir
se lo inyecta.</div>
<div class="MsoNormal" style="margin-left: 35.4pt; text-indent: 18.0pt;">
Zonificación
en edificios en edificios de oficinas</div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 71.4pt; mso-add-space: auto; mso-list: l1 level1 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Zona perimetral, es la distancia de 5 mts. a
partir del muro exterior, que se considera expuesta a la acción variable del
clima y del sol, desde un máximo en verano por radiación solar, trasmisiones de
calor, disminuyendo luego en las estaciones intermedias hasta presentarse como
una zona con pérdida de calor.</div>
<div class="MsoListParagraphCxSpMiddle">
<br /></div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l2 level1 lfo8; text-indent: -18.0pt;">
<!--[if !supportLists]-->4.<span style="font-size: 7pt;">
</span><!--[endif]-->¿A qué nos referimos con distribución de aire?</div>
<div class="MsoNormal">
A la manera de cómo distribuimos el aire en los locales. Está
relacionado con la manera de regular el calor sensible necesario a extraer,
depende del caudal de aire circulante y de la temperatura del aire de impulsión
al local.</div>
<div class="MsoNormal">
QSi = 17 . C . (ti –
tI )</div>
<div class="MsoNoSpacing" style="text-indent: 18.0pt;">
Donde:</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l4 level1 lfo6; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->QSi
: calor sensible a extraer del interior del local (Kcal / h)</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l4 level1 lfo6; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->C:
caudal de aire circulante (m3 / min)</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l4 level1 lfo6; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->ti:
temperatura de diseño interior o <b>retorno</b>
(°C)</div>
<div class="MsoNoSpacing" style="margin-left: 36.0pt; mso-list: l4 level1 lfo6; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;"> </span></span><!--[endif]-->tI
: temperatura del <b>aire de impulsión</b>
al local (°C)</div>
<div class="MsoNoSpacing">
<br /></div>
<div class="MsoNormal">
Como la temperatura de diseño o retorno debe ser constante,
se tiene dos posibilidades:</div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo9; text-indent: -18.0pt;">
<!--[if !supportLists]-->1.<span style="font-size: 7pt;">
</span><!--[endif]--><b>Variar el
caudal de aire circulante</b>, se varía el caudal manteniendo constante la
temperatura de impulsión, denominada <b>Volumen
Variable (VAV).</b></div>
<div class="MsoListParagraphCxSpMiddle" style="text-indent: 17.4pt;">
Puede ser zonal,
individual o central.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 53.4pt; mso-add-space: auto; text-indent: 1.9pt;">
Son persianas, denominadas Dampers, que se insertan en
los conductos, si se emplean en equipos con ventiladores de caudal constante,
el cierre parcial de estas generan una inaceptable sobrepresión dentro de los
conductos. Para mantener la presión constante se coloca un conducto en by-pass
en el pleno de mezcla. Estas rejas pueden ser barométricas o mecánicas
comandadas por el mismo termostato que regula el caudal de aire interior</div>
<div class="MsoListParagraphCxSpLast">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgYOy_l02fBXojgozIYOaaa7ZuQEd6lEb_-Rgp9QhUtTaykrRJ6PFh0LetdMh5mGA5F-dvPOwpEipLrwMN90N7X4OuZ9IS8kZSP8N8irDQSkLUa6dUMXL_8PjmNz7NwBXxTTtcf9wA-P3A/s1600/roof+top2.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="330" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgYOy_l02fBXojgozIYOaaa7ZuQEd6lEb_-Rgp9QhUtTaykrRJ6PFh0LetdMh5mGA5F-dvPOwpEipLrwMN90N7X4OuZ9IS8kZSP8N8irDQSkLUa6dUMXL_8PjmNz7NwBXxTTtcf9wA-P3A/s400/roof+top2.JPG" width="400" /></a></div>
<div class="MsoNormal">
<br />
<!--[endif]--></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoListParagraph" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo9; text-indent: -18.0pt;">
<!--[if !supportLists]-->2.<span style="font-size: 7pt;">
</span><!--[endif]--><b>Variar la
temperatura del aire de impulsión
manteniendo constante el caudal de aire,</b> mediante un termostato, se detiene el
compresor del equipo de modo que el serpentín va aumentando gradualmente su
temperatura y con el aire impulsado, disminuyendo la extracción de calor sensible.</div>
<div class="MsoNormal" style="margin-left: 18.0pt;">
En ambos casos no se detiene el
ventilador, ni se lo utiliza como forma de regulación, ya que debe funcionar en
todo momento garantizando el barrido de aire y la entrada de aire nuevo de
ventilación, admitiendo un porcentaje mínimo de abertura del 15% para VAV, o
bien hacer ingresar aire nuevo del exterior en forma independiente, con una
unidad de tratamiento especifica. Esto genera un gasto innecesario de energía,
el cual puede ahorrarse utilizando un ventilador con motor de velocidad
variable, su característica es similar a los compresores en los equipos VRV,
uno de los problemas es que al reducir el caudal circulatorio también lo hace
el aire exterior de ventilación,</div>
<div class="MsoNormal" style="margin-left: 18.0pt;">
<br /></div>
<br />
<b><span style="font-family: "Calibri","sans-serif"; font-size: 11.0pt; mso-ansi-language: ES-AR; mso-ascii-theme-font: minor-latin; mso-bidi-font-family: "Times New Roman"; mso-bidi-language: AR-SA; mso-bidi-theme-font: minor-bidi; mso-fareast-font-family: Calibri; mso-fareast-language: EN-US; mso-fareast-theme-font: minor-latin; mso-hansi-theme-font: minor-latin; text-transform: uppercase;"> DISTRIBUCION DE AIRE BAJO PISO (UFAD) </span></b><span style="font-family: "Calibri","sans-serif"; font-size: 11.0pt; mso-ansi-language: ES-AR; mso-ascii-theme-font: minor-latin; mso-bidi-font-family: "Times New Roman"; mso-bidi-language: AR-SA; mso-bidi-theme-font: minor-bidi; mso-fareast-font-family: Calibri; mso-fareast-language: EN-US; mso-fareast-theme-font: minor-latin; mso-hansi-theme-font: minor-latin;">Este aprovecha el piso técnico elevado para la
distribución del aire desde una unidad de tratamiento con ventilador de caudal
variable y se utiliza el cielorraso armado como pleno de retorno, se lo
denomina “under floor air distribution”, es un sistema todo aire. La
distribución se realiza por convección natural o bien por el desplazamiento del
aire que es impulsado a baja velocidad y a una temperatura mayor que lo normal,
para evitar corrientes frías y baje mucho la temperatura del piso, se utilizan
difusores de piso de flujo helicoidal de baja velocidad. La ventaja principal
es su bajo consumo ya que el volumen que se enfría, no es la totalidad del
ambiente, sino hasta la parte más alta de la zona de ocupación de
aproximadamente 2 m de altura, despreciándose las cargas sensibles de las
luminarias y todo lo que esté por encima. No es un sistema recomendable para
calefacción</span>ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-82196205518270134532013-02-15T09:28:00.000-08:002013-02-15T09:28:06.548-08:00MATERIALES DE LOS CONDUCTOS DE AIRE ACONDICIONADO<br />
<div class="MsoNormal" style="margin-left: 18.0pt;">
<b><span style="text-transform: uppercase;">MATERIALES DE LOS CONDUCTOS DE
AIRE ACONDICIONADO<o:p></o:p></span></b></div>
<div class="MsoNormal">
En cuanto a la velocidad se los puede clasificar en:</div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l1 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Baja velocidad: hasta 600 m/min</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l1 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Alta velocidad: más de 600 m/min</div>
<div class="MsoNormal">
Pueden ser de distintos materiales:</div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l0 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->De Aluminio o Chapa galvanizada, se unen
herméticamente mediante pliegues, cuando
es necesario modificar la forma del conducto se recomienda una inclinación de 25°C
y que la reducción de área no sea mayor del 20%. En el montaje de conductos
debe evitarse la propagación de vibraciones mediante juntas antivibratorias de
lona o plástico, las curvas deben ser de amplio radio mayor a los ¾ de la
dimensión del conducto. A fin de evitar turbulencias toda desviación debe
separarse 3 veces del diámetro o la anchura del conducto de las curvas. Su
aislamiento es con lana mineral, de vidrio, polietileno expandido de 25mm en el
interior y 50mm en exteriores, los conductos de retorno interiores no se
aíslan, pero si el retorno esta al exterior se aíslan con un espesor de 25mm</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l0 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Plástico, son flexibles con una estructura
rígida de alambre, pueden venir con la aislación incorporada, se utilizan
entramos cortos y de difícil acceso. Para su instalación se debe ejecutar cajas
de unión de chapa galvanizada.</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l0 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->De lana de vidrio o espumas rígidas conforman
todo un conjunto conducto-aislación, que se van cortando y uniendo mediante
pegamento por tramos y accesorios. Están compuestos de fibra de vidrio de alta
densidad con una fina chapa de aluminio interior y otra exterior que actúa como
barrera vapor</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l0 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Mampostería</div>
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-44684414769735404122013-02-15T09:26:00.000-08:002013-02-15T09:27:01.182-08:00COMPONENTES DE LAS INSTALACIONES<br />
<div class="MsoNormal" style="margin-left: 18.0pt;">
<b><span style="text-transform: uppercase;">COMPONENTES DE LAS INSTALACIONES<o:p></o:p></span></b></div>
<div class="MsoNormal">
Ademas de los conductos, los elementos básicos que se
emplean en las instalaciones de aire acondicionado o ventilación mecánica son:</div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l2 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Ventiladores</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Centrífugos</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l2 level3 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Curvadas hacia adelante, son los más silenciosos
y más utilizados </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l2 level3 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Curvada hacia atrás, son utilizados en
equipamientos más grandes, son algo ruidosos</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l2 level3 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Con aletas radiales, se utilizan en
instalaciones grandes, son algo ruidosos, por la forma de sus paletas son auto
limpiante.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Axiles</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Helicoidales, se emplean para extracción de aire
directa, sin conductos</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Axiles </div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Persianas fijas o regulables</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Fijas tipo celosías</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->regulables</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l2 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Filtros de aire</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l2 level1 lfo3; text-indent: -18.0pt;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiK608lTXjWXi5FHuOXHVqlmjPCRr3DhM3X_dLj0geMFymtVwjO8ooshIkw-G2aK7RGAHbm_81j3mJ7T5_x0b1HibK6FHgtRlkqYMnhf_pIwfkEzq_J_bGsBWH5Nw6MF1o7jdkCI75_sPk/s1600/filtros.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="130" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiK608lTXjWXi5FHuOXHVqlmjPCRr3DhM3X_dLj0geMFymtVwjO8ooshIkw-G2aK7RGAHbm_81j3mJ7T5_x0b1HibK6FHgtRlkqYMnhf_pIwfkEzq_J_bGsBWH5Nw6MF1o7jdkCI75_sPk/s400/filtros.JPG" width="400" /></a></div>
<div class="MsoNormal" style="margin-left: 35.4pt; text-indent: 35.4pt;">
<br />
<!--[endif]--></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->De superficie plana</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l2 level3 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Metálicos, están compuestos por una serie de 7 o
mas mallas de alambre superpuestas, embebidas en aceite mineral, son lavables,
pero se ha dejado de usar.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l2 level3 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->De fibra, formados por filamentos largos y
continuos unidos con adhesivos para incrementar su retención, generando una
estructura laberíntica de una densidad que aumenta en el sentido del avance del
aire. Las fibras pueden ser de lana de vidrio, de poliéster, de polipropileno o
nylon. Son desechables y vienen con un marco de cartón que les da rigidez.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l2 level3 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->De poliuretano, son de baja eficiencia, lavables
y se aplica en equipos split con el objeto de proteger la batería de
refrigeración y el ventilador.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->De superficie expandida</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l2 level3 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Plisados, son de mediana eficiencia,
descartables, están compuestos por fibras de algodón reforzadas con sintéticas,
plegados de modo de alcanzar una superficie filtrante de 4 veces su área
frontal. Toda su superficie esta soportada por una malla de alambre soldado, se
emplean como pre filtros para los filtros absolutos.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l2 level3 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->De bolsa, están compuestos por un manto de
fibras de vidrio o sintéticas ultra finas mezcladas con un aditivo especial, su
plegado hace formar bolsas individuales sustentadas por un marco rígido, son de
gran eficiencia.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l2 level3 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Absolutos, denominados HEPA, son desechables,
compuestos por un marco rígido y un manto de fibras de vidrio o sintéticas de
diámetro inferior a 1 micrón que se pliega entre unos separadores de aluminio,
se emplean en mano factura de micro electrónicos, salas de terapia, etc. Para
preservar su vida útil es necesario utilizar pre filtros como los plisados.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Filtros electrostáticos</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l2 level3 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Wingdings; mso-bidi-font-family: Wingdings; mso-fareast-font-family: Wingdings;">§<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Aprovechan los campos electromagnéticos para
extraer los contaminantes. Son de alta eficiencia y pueden filtrar partículas
muy contaminantes como las del humo, niebla, etc. Pueden completarse con
filtros de carbón activado o lámparas germicidas para remover olores y destruir
bacterias</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Guiadores</div>
<div class="MsoListParagraphCxSpMiddle">
<br /></div>
<div class="MsoListParagraphCxSpMiddle">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhzu7UJb8I7qfrmcudb6mAnAjEWtLh1utEfwOQHtXNzFsvGTDsr1Jn_QkBolUvX4JUVUKIepBUyZszZYQwNLvMJeu0jMq78DLZQRdoCUY-_b-WSCJuRTtxt3dPsmqv1_B5VMWEyl0b1lcU/s1600/Damper.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="137" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhzu7UJb8I7qfrmcudb6mAnAjEWtLh1utEfwOQHtXNzFsvGTDsr1Jn_QkBolUvX4JUVUKIepBUyZszZYQwNLvMJeu0jMq78DLZQRdoCUY-_b-WSCJuRTtxt3dPsmqv1_B5VMWEyl0b1lcU/s320/Damper.JPG" width="320" /></a></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh_FjOj6z_XdnuCEFnj6SFhbyYcDpQ8ZK4VTUmmGqdhaFGgnQlAt72TNL19-wns9hSAPzylOoRcmcnfNgdzBM-eIf4Dcq0efY6v1IN5oRqcXO1EdFMtAO05fjwasMhoUpN6tVgo_iXIcCM/s1600/volumen+de+aire+variable2.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="281" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh_FjOj6z_XdnuCEFnj6SFhbyYcDpQ8ZK4VTUmmGqdhaFGgnQlAt72TNL19-wns9hSAPzylOoRcmcnfNgdzBM-eIf4Dcq0efY6v1IN5oRqcXO1EdFMtAO05fjwasMhoUpN6tVgo_iXIcCM/s400/volumen+de+aire+variable2.JPG" width="400" /></a></div>
<div class="separator" style="clear: both; text-align: center;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle">
<br />
<!--[endif]--></div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Dampers <!--[endif]--></div>
<div class="MsoListParagraphCxSpMiddle">
<br /></div>
<div class="MsoListParagraphCxSpMiddle">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Cajas V.A.V (Volumen de Aire Variable)</div>
<div class="MsoListParagraphCxSpLast">
Son persianas que se insertan en los
conductos, el cierre parcial de estas generan una inaceptable sobrepresión
dentro de los conductos. Para mantener la presión constante se coloca un
conducto en by-pass en el pleno de mezcla. Estas rejas pueden ser barométricas
o mecánicas comandadas por el m ismo termostato que regula el caudal de aire
interior</div>
<div class="MsoListParagraphCxSpLast">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgv6Atma1vMSsUxPgA6bRZQj8GUxW2MRYF4c3woK4EuquCRCFBz5OJC24fxzuJSimd3ezV1N9dUcegDhuNEy-JJo0WLgWTugy1XVeu2lMYala4WAt5ctRwpI45QvrKjCYPI1lxMQIxqsr0/s1600/cajas+VAV.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="127" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgv6Atma1vMSsUxPgA6bRZQj8GUxW2MRYF4c3woK4EuquCRCFBz5OJC24fxzuJSimd3ezV1N9dUcegDhuNEy-JJo0WLgWTugy1XVeu2lMYala4WAt5ctRwpI45QvrKjCYPI1lxMQIxqsr0/s400/cajas+VAV.JPG" width="400" /></a></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br />
<!--[endif]--></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 72.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Protección para evitar ingresos no deseados</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Calefacción de conductos</div>
<div class="MsoListParagraphCxSpMiddle">
Mediante una resistencia térmica se
calienta el aire frio para aquellos locales que hayan llegado al confort y
compartan el mismo conducto con otros locales que no lo han alcanzado.</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Persianas regulables</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Deflectores</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->PIEZAS ESPECIALES</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><!--[if gte vml 1]><v:shape id="Imagen_x0020_9"
o:spid="_x0000_s1029" type="#_x0000_t75" style='position:absolute;left:0;
text-align:left;margin-left:61.85pt;margin-top:18.7pt;width:178.5pt;height:73.4pt;
z-index:-4;visibility:visible;mso-wrap-style:square;mso-wrap-distance-left:9pt;
mso-wrap-distance-top:0;mso-wrap-distance-right:9pt;
mso-wrap-distance-bottom:0;mso-position-horizontal:absolute;
mso-position-horizontal-relative:text;mso-position-vertical:absolute;
mso-position-vertical-relative:text'>
<v:imagedata src="file:///C:\Users\Facundo\AppData\Local\Temp\msohtmlclip1\01\clip_image009.jpg"
o:title="CURVAS"/>
</v:shape><![endif]--><!--[if !vml]--><span style="height: 98px; left: 0px; margin-left: 83px; margin-top: 25px; mso-ignore: vglayout; position: absolute; width: 238px; z-index: -4;"><img height="98" src="file:///C:/Users/Facundo/AppData/Local/Temp/msohtmlclip1/01/clip_image010.jpg" v:shapes="Imagen_x0020_9" width="238" /></span><!--[endif]-->Curvas</div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhTiyGDPGJtjcijr6KrWdSN0odk5rgPl6yg6FuqTE5P2OSHMyXZSExypTihlm6HtGEUQchqSZwA8yHlOOG6HPsUT9e3tyJMGCpoMw0hL9fB2OrsXh3dg1-AGQmxYsjCOBkT86QbM7-vGh4/s1600/CURVAS.JPG" imageanchor="1" style="clear: left; float: left; margin-bottom: 1em; margin-right: 1em;"><img border="0" height="81" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhTiyGDPGJtjcijr6KrWdSN0odk5rgPl6yg6FuqTE5P2OSHMyXZSExypTihlm6HtGEUQchqSZwA8yHlOOG6HPsUT9e3tyJMGCpoMw0hL9fB2OrsXh3dg1-AGQmxYsjCOBkT86QbM7-vGh4/s200/CURVAS.JPG" width="200" /></a></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<o:p><br /></o:p></div>
<div class="MsoNormal">
<o:p><br /></o:p></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Curvas con Guiadores</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto;">
<!--[if gte vml 1]><v:shape
id="Imagen_x0020_10" o:spid="_x0000_s1028" type="#_x0000_t75" style='position:absolute;
left:0;text-align:left;margin-left:61.9pt;margin-top:1.75pt;width:196.75pt;
height:87.2pt;z-index:-3;visibility:visible;mso-wrap-style:square;
mso-wrap-distance-left:9pt;mso-wrap-distance-top:0;mso-wrap-distance-right:9pt;
mso-wrap-distance-bottom:0;mso-position-horizontal:absolute;
mso-position-horizontal-relative:text;mso-position-vertical:absolute;
mso-position-vertical-relative:text'>
<v:imagedata src="file:///C:\Users\Facundo\AppData\Local\Temp\msohtmlclip1\01\clip_image011.jpg"
o:title="CURVAS CON GUIADORES"/>
</v:shape><![endif]--><!--[if !vml]--><span style="height: 116px; left: 0px; margin-left: 83px; margin-top: 2px; mso-ignore: vglayout; position: absolute; width: 262px; z-index: -3;"><img height="116" src="file:///C:/Users/Facundo/AppData/Local/Temp/msohtmlclip1/01/clip_image012.jpg" v:shapes="Imagen_x0020_10" width="262" /></span><!--[endif]--></div>
<div class="MsoNormal">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEghPO2qrvp4jR5Fh4Bq8_cM0ek7sylw0NYuGlcdCu_vp98IUHHPrHrhCjKk6RYT_5ljCJdOPFTi5EVWe7LpN1BeXOI2zN5ujjavpPBf8-1adX-o9IS01x1LukunnqQIWtrz8vscwkRXSlM/s1600/CURVAS+CON+GUIADORES.JPG" imageanchor="1" style="clear: left; float: left; margin-bottom: 1em; margin-right: 1em;"><img border="0" height="88" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEghPO2qrvp4jR5Fh4Bq8_cM0ek7sylw0NYuGlcdCu_vp98IUHHPrHrhCjKk6RYT_5ljCJdOPFTi5EVWe7LpN1BeXOI2zN5ujjavpPBf8-1adX-o9IS01x1LukunnqQIWtrz8vscwkRXSlM/s200/CURVAS+CON+GUIADORES.JPG" width="200" /></a></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<o:p><br /></o:p></div>
<div class="MsoNormal">
<o:p><br /></o:p></div>
<div class="MsoNormal">
<o:p><br /></o:p></div>
<div class="MsoNormal">
<o:p><br /></o:p></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Desvíos</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Bifurcaciones</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Reducciones</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Ampliaciones</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><!--[if gte vml 1]><v:shape id="Imagen_x0020_13"
o:spid="_x0000_s1027" type="#_x0000_t75" style='position:absolute;left:0;
text-align:left;margin-left:61.9pt;margin-top:20.6pt;width:199.15pt;height:87pt;
z-index:-2;visibility:visible;mso-wrap-style:square;mso-wrap-distance-left:9pt;
mso-wrap-distance-top:0;mso-wrap-distance-right:9pt;
mso-wrap-distance-bottom:0;mso-position-horizontal:absolute;
mso-position-horizontal-relative:text;mso-position-vertical:absolute;
mso-position-vertical-relative:text'>
<v:imagedata src="file:///C:\Users\Facundo\AppData\Local\Temp\msohtmlclip1\01\clip_image013.jpg"
o:title="COLLAR Y COLCHON TERMINAL"/>
</v:shape><![endif]--><!--[if !vml]--><span style="height: 116px; left: 0px; margin-left: 83px; margin-top: 27px; mso-ignore: vglayout; position: absolute; width: 266px; z-index: -2;"><img height="116" src="file:///C:/Users/Facundo/AppData/Local/Temp/msohtmlclip1/01/clip_image014.jpg" v:shapes="Imagen_x0020_13" width="266" /></span><!--[endif]-->Collares y Colchón Terminal</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhiGTSDw_t3XYZw4fr9RLt4Qt9DCyUqQxmPv-cxEdDp5v9zLj9sF1r5lT_40wRE8sfNgySGSYaWaYjWN_QkSDAAtIETbo7GxmD3Oc1HNOVG4WSNjqXiZi1PRh9bogBd9ySqHA0Xnla4dhg/s1600/COLLAR+Y+COLCHON+TERMINAL.JPG" imageanchor="1" style="clear: left; float: left; margin-bottom: 1em; margin-right: 1em;"><img border="0" height="86" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhiGTSDw_t3XYZw4fr9RLt4Qt9DCyUqQxmPv-cxEdDp5v9zLj9sF1r5lT_40wRE8sfNgySGSYaWaYjWN_QkSDAAtIETbo7GxmD3Oc1HNOVG4WSNjqXiZi1PRh9bogBd9ySqHA0Xnla4dhg/s200/COLLAR+Y+COLCHON+TERMINAL.JPG" width="200" /></a></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<o:p><br /></o:p></div>
<div class="MsoNormal">
<o:p><br /></o:p></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<span style="font-size: 7pt; text-indent: -18pt;"> </span></div>
<div class="MsoListParagraph" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[endif]--><!--[if gte vml 1]><v:shape id="Imagen_x0020_15"
o:spid="_x0000_s1026" type="#_x0000_t75" style='position:absolute;left:0;
text-align:left;margin-left:67.15pt;margin-top:15.8pt;width:207.3pt;height:87.9pt;
z-index:-1;visibility:visible;mso-wrap-style:square;mso-wrap-distance-left:9pt;
mso-wrap-distance-top:0;mso-wrap-distance-right:9pt;
mso-wrap-distance-bottom:0;mso-position-horizontal:absolute;
mso-position-horizontal-relative:text;mso-position-vertical:absolute;
mso-position-vertical-relative:text'>
<v:imagedata src="file:///C:\Users\Facundo\AppData\Local\Temp\msohtmlclip1\01\clip_image015.jpg"
o:title="PANTALON"/>
</v:shape><![endif]--><!--[if !vml]--><span style="height: 117px; left: 0px; margin-left: 90px; margin-top: 21px; mso-ignore: vglayout; position: absolute; width: 276px; z-index: -1;"><img height="117" src="file:///C:/Users/Facundo/AppData/Local/Temp/msohtmlclip1/01/clip_image016.jpg" v:shapes="Imagen_x0020_15" width="276" /></span><!--[endif]-->Pantalón</div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhexhjoGbB6C7TzgFpb5y-ZgnIYEW3nlscPmu4hb5bRbCRHQcwQtNLV4CAFUbx5DIzVleiR_8c3ChK_0dgqqLn3p3iSxP_hEM7QtLUZoIccvs3bKoMvuVWHZJY4HARefZaUgfzWsbK-Ye8/s1600/PANTALON.JPG" imageanchor="1" style="clear: left; float: left; margin-bottom: 1em; margin-right: 1em;"><img border="0" height="84" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhexhjoGbB6C7TzgFpb5y-ZgnIYEW3nlscPmu4hb5bRbCRHQcwQtNLV4CAFUbx5DIzVleiR_8c3ChK_0dgqqLn3p3iSxP_hEM7QtLUZoIccvs3bKoMvuVWHZJY4HARefZaUgfzWsbK-Ye8/s200/PANTALON.JPG" width="200" /></a></div>
<div class="MsoNormal" style="margin-left: 18.6pt; text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="margin-left: 18.6pt; text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="margin-left: 18.6pt; text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoListParagraph" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Tomas</div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<b><span style="text-transform: uppercase;">DISTRIBUCION DEL AIRE EN LOS
LOCALES<o:p></o:p></span></b></div>
<div class="MsoNormal">
Los elementos que se utilizan para distribuir el aire
acondicionado son de chapa o aluminio y según su ubicación se los denomina:</div>
<div class="MsoListParagraph" style="mso-list: l1 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Toberas<o:p></o:p></b></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgjd40Z2KKCXu9qM14Fsmj626PdgSMPArVes3hwpLHAjqbmZNSybJAZz4K0f2EHBZXlB5AIh8-B-OLHc-nWzWpQH4vwDBAbaGwujExzh9LVHC7bTJMRWDPjaiABFjmdFfixy7ahsunOqs0/s1600/TOBERA.JPG" imageanchor="1" style="clear: left; float: left; margin-bottom: 1em; margin-right: 1em;"><img border="0" height="190" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgjd40Z2KKCXu9qM14Fsmj626PdgSMPArVes3hwpLHAjqbmZNSybJAZz4K0f2EHBZXlB5AIh8-B-OLHc-nWzWpQH4vwDBAbaGwujExzh9LVHC7bTJMRWDPjaiABFjmdFfixy7ahsunOqs0/s200/TOBERA.JPG" width="200" /></a></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<br /></div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l1 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Rejas de
Mando y/o Retorno</b>: ubicadas en la pared inyectando o retornando aire en
forma horizontal</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Inyección</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Retorno</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Fijas</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Regulación de Caudal</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Regulación de Orientación</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Verticales</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Horizontales</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Rectangulares</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Cuadradas</div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgv_zkzPKD1ruDg030nLrLgzEQvyfBfCPKpRz_oceq0NxR-LHIeX_ZSE_lpC4zdnfeNv3CjINLHdtnGgYAPfkX8ZfR5-4PwH71ASgV7HWot331W3HPX5cdlSBPusQLsKuPJTT3WMfPskDo/s1600/rejas+de+retorno.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="320" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgv_zkzPKD1ruDg030nLrLgzEQvyfBfCPKpRz_oceq0NxR-LHIeX_ZSE_lpC4zdnfeNv3CjINLHdtnGgYAPfkX8ZfR5-4PwH71ASgV7HWot331W3HPX5cdlSBPusQLsKuPJTT3WMfPskDo/s320/rejas+de+retorno.JPG" width="137" /></a></div>
<br />
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhhHTll9kSesel19Z9A1w4gr6AJ_BPDH304TExRZEFp2x2pEa1aCunXmwVk9-qBl-zil1gjSM1QE2JwtjOt5f4kM5Nd5SrbCpON6OdQWedV4MSweU_0bRhSq3tjeeYG9PIhKl8wgCNzY8U/s1600/rejas+de+mando.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="312" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhhHTll9kSesel19Z9A1w4gr6AJ_BPDH304TExRZEFp2x2pEa1aCunXmwVk9-qBl-zil1gjSM1QE2JwtjOt5f4kM5Nd5SrbCpON6OdQWedV4MSweU_0bRhSq3tjeeYG9PIhKl8wgCNzY8U/s320/rejas+de+mando.JPG" width="320" /></a></div>
<div class="MsoNormal" style="text-indent: 35.4pt;">
<!--[endif]--></div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l1 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Difusores
de Mando y/o Retorno</b>: colocados en cielorrasos suministrando aire en forma
vertical (lineal, ubicada en el perímetro enfrente a ventanas) o colocados en
piso suministrando aire en forma helicoidal.</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Mando</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Retorno</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Mando y Retorno</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Circulares</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Rectangulares</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Cuadrados</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Lineales</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l2 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->De piso</div>
<div class="MsoNormal" style="margin-left: 54.0pt;">
Su cálculo es:</div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l1 level2 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]--><b>Primero</b>,
establecer el caudal de aire:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
Caudal de aire frio: C= Qsi / 170</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
Donde:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l0 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Qsi: ganancia de calor sensible (Kcal / h)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l0 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->170: factor que surge de las diferencias de
temperaturas entre el aire de retorno y de alimentación, el peso y calor
especifico del aire</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 70.8pt; mso-add-space: auto;">
<b>Segundo</b>, obtenido el caudal
total se establece una cantidad de difusores o rejas se va a inyectar el aire
en el local y sabiendo el largo del local se va a la tabla de selección de rejas
de inyección y se obtiene sus dimensiones A = C / V</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
Donde:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l0 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->A: área de la reja o difusor</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l0 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->C: el caudal destinado a pasara por esa reja o difusores,
si se destinan 4 rejas se debe dividir el caudal total ya mencionado por 4</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l0 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->V: velocidad de trabajo, generalmente 300 m/min</div>
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-64170882899833701932013-02-15T09:08:00.002-08:002013-02-15T09:16:27.151-08:00CALCULO DE LAS CAÑERIAS Y CONDUCTOS<div class="MsoNormal" style="margin-left: 18.0pt;">
<br />Para calcular los diámetros de las cañerías de agua o los
conductos se debe determinar:</div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l1 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->C: caudal, es la cantidad de fluido medido en
volumen, que circula en la unidad de tiempo a través de la sección transversal
de una canalización. Se mide en: Litro / h, m3/min, etc.</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l1 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->R: gradiente hidráulico: es la perdida de
presión por metro, por efecto de los frotamientos que se producen en la circulación
del fluido por las canalizaciones y se mide normalmente en milímetro de columna
de agua por metro (mm.c.a. / m), y equivale a 1 kg/m2</div>
<div class="MsoNormal" style="margin-left: 18.0pt;">
<b><span style="text-transform: uppercase;">METODO DE CALCULO DE FRICCION
CONSTANTE<o:p></o:p></span></b></div>
<div class="MsoNormal">
Se basa en la suposición de un gradiente hidráulico R
(mmca/m) de caída de presión uniforme a lo largo de toda la canalización. Este
gradiente se determina en el tramo principal, con el caudal máximo transportado
que es el de la bomba o ventilador, fijando una máxima velocidad de
circulación. Esta velocidad máxima se establece en virtud de razones económicas
teniendo en cuenta no superar valores tolerables en cuanto a niveles de ruido o
erosión de las canalizaciones. De esa manera, se puede determinar el diámetro
del tramo principal de la red y allí nace la recta de maniobra, que es un valor
de R constante, que permite seleccionar los diámetros de los otros tramos de la
canalización, en función de sus caudales circulantes.</div>
<div class="MsoNormal" style="margin-left: 18.0pt;">
<b><span style="text-transform: uppercase;">CALCULO DE LOS DISPOSITIVOS DE
TRANSPORTES DEL FLUIDO<o:p></o:p></span></b></div>
<div class="MsoNormal">
Para la característica de la bomba o el ventilador debe
establecerse el caudal y la presión que se debe disponer para producir el
movimiento. Se estima con la siguiente fórmula:</div>
<div class="MsoNormal">
H = (2 . ∑I . R) + (∑Z)</div>
<div class="MsoNormal">
Donde:</div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l0 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->H: presión de la bomba (mca) o ventilador (mmca)</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l0 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->(2 . ∑I . R): perdida de carga total por
frotamiento de los tramos rectos de cañerías y accesorios del circuito cerrado
mas desfavorable o mas largo de la canalización, constituido por los tramos de
alimentación y retorno (mmca) el numero 2 surge de considerar que en el
circuito, la caída de presión en los accesorios es igual al de los tramos
rectos de las cañerías</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l0 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->R: gradiente hidráulico (mmca/m)</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l0 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->∑I : sumatoria de la longitud de los
tramos rectos del circuito (m)</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l0 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->∑ Z : sumatoria de los frotameintos
producidos por ( mmca):</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l0 level2 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->La unidad enfriadora</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l0 level2 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Los fan-coil</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l0 level2 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Rejas</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l0 level2 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Persianas</div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l0 level2 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: "Courier New"; mso-fareast-font-family: "Courier New";">o<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Difusores, tec.</div>
<br />
<div class="MsoNormal" style="margin-left: 18.0pt; text-indent: 17.4pt;">
<b><span style="text-transform: uppercase;">CALCULO
DE CONDUCTOS DE AIRE<o:p></o:p></span></b></div>
<div class="MsoNormal">
Se emplea el abaco, donde se establece la relación entre el
caudal de aire (m3/min) y el gradiente R (mmca/m), para una determinada
velocidad de circulación (m7min) y el diámetro del conducto (cm)</div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l5 level1 lfo6; text-indent: -18.0pt;">
<!--[if !supportLists]-->1.<span style="font-size: 7pt;">
</span><!--[endif]-->Primero, establecer el caudal de aire:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l5 level2 lfo6; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Caudal de aire frio : C= Qsi / 170</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
Donde:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
Qsi: ganancia de calor sensible (Kcal / h)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
170: factor que surge de las diferencias de temperaturas entre el aire de
retorno y de alimentación, el peso y calor especifico del aire</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l5 level1 lfo6; text-indent: -18.0pt;">
<!--[if !supportLists]-->2.<span style="font-size: 7pt;">
</span><!--[endif]-->Segundo, obtenido el caudal total se establece
una cantidad de difusores o rejas se va a inyectar el aire en el local y
sabiendo el largo del local se va a la tabla de selección de rejas de inyección
y se obtiene sus dimensiones. Donde:</div>
<div class="MsoListParagraphCxSpMiddle">
A = C / V</div>
<div class="MsoListParagraphCxSpMiddle">
A: area de la reja o difusor</div>
<div class="MsoListParagraphCxSpMiddle">
C: el caudal destinado a pasara por esa
reja o difusors, si se destinan 4 rejas se debe dividir el caudal total ya
mencionado por 4</div>
<div class="MsoListParagraphCxSpMiddle">
V: velocidad de trabajo, generalmente 300
m/min</div>
<div class="MsoListParagraphCxSpMiddle">
<br /></div>
<div class="MsoListParagraphCxSpMiddle">
Se divide el caudal total por la cantidad
de rejas o difusores y ese va a ser la demanda en cada punto, teniendo en
cuenta que entre más nos acerquemos a la maquina enfriadora se va sumando el
caudal de la reja precedente.</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l5 level1 lfo6; text-indent: -18.0pt;">
<!--[if !supportLists]-->3.<span style="font-size: 7pt;">
</span><!--[endif]-->Tercero, establecer la velocidad máxima, de
acuerdo al uso que se de en el interior del local:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l5 level2 lfo6; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Locales industriales: 500 m/min</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l5 level2 lfo6; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Oficinas de personal: 300 a 450 m/min</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l5 level2 lfo6; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Viviendas: 300 m / min</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l5 level1 lfo6; text-indent: -18.0pt;">
<!--[if !supportLists]-->4.<span style="font-size: 7pt;">
</span><!--[endif]-->Cuarto, fijada la velocidad máxima y el caudal
se obtiene del Abaco la recta de maniobra R constante, del cual salen los
DIAMETROS de cada conducto, de acuerdo a la demanda del caudal en cada reja o
difusor. </div>
<div class="MsoNormal">
<!--[if gte vml 1]><v:shapetype
id="_x0000_t75" coordsize="21600,21600" o:spt="75" o:preferrelative="t"
path="m@4@5l@4@11@9@11@9@5xe" filled="f" stroked="f">
<v:stroke joinstyle="miter"/>
<v:formulas>
<v:f eqn="if lineDrawn pixelLineWidth 0"/>
<v:f eqn="sum @0 1 0"/>
<v:f eqn="sum 0 0 @1"/>
<v:f eqn="prod @2 1 2"/>
<v:f eqn="prod @3 21600 pixelWidth"/>
<v:f eqn="prod @3 21600 pixelHeight"/>
<v:f eqn="sum @0 0 1"/>
<v:f eqn="prod @6 1 2"/>
<v:f eqn="prod @7 21600 pixelWidth"/>
<v:f eqn="sum @8 21600 0"/>
<v:f eqn="prod @7 21600 pixelHeight"/>
<v:f eqn="sum @10 21600 0"/>
</v:formulas>
<v:path o:extrusionok="f" gradientshapeok="t" o:connecttype="rect"/>
<o:lock v:ext="edit" aspectratio="t"/>
</v:shapetype><v:shape id="Imagen_x0020_19" o:spid="_x0000_i1027" type="#_x0000_t75"
style='width:478.95pt;height:452.05pt;visibility:visible;mso-wrap-style:square'>
<v:imagedata src="file:///C:\Users\Facundo\AppData\Local\Temp\msohtmlclip1\01\clip_image001.jpg"
o:title="CALCULO DE CONDUCTOS EJEMPLO"/>
</v:shape><![endif]--><!--[if !vml]--><!--[endif]--></div>
<div class="MsoNormal">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEieRufk4_pQLhDOrTwqIopYbbZ3V3gzu7hvjJOpZ6yHchOfi-6hOcdON1dAFlakG2vAdB_HPealGHlcdR6P_0mEWGTz1i_rpioc4vYW8SRaFgPe3G8EK0AajLM9hh9dbQCYXbOhyphenhyphenvBRybw/s1600/CALCULO+DE+CONDUCTOS+EJEMPLO.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="377" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEieRufk4_pQLhDOrTwqIopYbbZ3V3gzu7hvjJOpZ6yHchOfi-6hOcdON1dAFlakG2vAdB_HPealGHlcdR6P_0mEWGTz1i_rpioc4vYW8SRaFgPe3G8EK0AajLM9hh9dbQCYXbOhyphenhyphenvBRybw/s400/CALCULO+DE+CONDUCTOS+EJEMPLO.JPG" width="400" /></a></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<!--[if gte vml 1]><v:shape
id="Imagen_x0020_20" o:spid="_x0000_i1026" type="#_x0000_t75" style='width:488.35pt;
height:370pt;visibility:visible;mso-wrap-style:square'>
<v:imagedata src="file:///C:\Users\Facundo\AppData\Local\Temp\msohtmlclip1\01\clip_image003.jpg"
o:title="CALCULO DE CONDUCTOS EJEMPLO 2"/>
</v:shape><![endif]--><!--[if !vml]--><!--[endif]--></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhv0fKPNU1qldIiEmyNtKVwcRiJe7TK_-9ScZsD0By6mpQe9GhwAIC7AWMLxpSFpyxYAMU7vA2Xdodc8JedGBu23IDP0AHSHfyQfqmv_kNmZGE2tV53W_niwi4vRO8vdxKVI5BLgnv3m3k/s1600/CALCULO+DE+CONDUCTOS+EJEMPLO+2.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="302" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhv0fKPNU1qldIiEmyNtKVwcRiJe7TK_-9ScZsD0By6mpQe9GhwAIC7AWMLxpSFpyxYAMU7vA2Xdodc8JedGBu23IDP0AHSHfyQfqmv_kNmZGE2tV53W_niwi4vRO8vdxKVI5BLgnv3m3k/s400/CALCULO+DE+CONDUCTOS+EJEMPLO+2.JPG" width="400" /></a></div>
<div class="separator" style="clear: both; text-align: center;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhYUTyuaqKfn_lfXca6cOKlYmnXfRNfXPYrvqPNTzpJgXaT2Wv5n42ajrsnVsYImykiSTOEUENIc_TTYnNp830_JZhAgRwihyphenhyphenOJYJT1zxrGtTyNjTI8GK2PH14DmgaRLzvO1DbefVjPliM/s1600/CALCULO+DE+CONDUCTOS.jpeg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="640" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhYUTyuaqKfn_lfXca6cOKlYmnXfRNfXPYrvqPNTzpJgXaT2Wv5n42ajrsnVsYImykiSTOEUENIc_TTYnNp830_JZhAgRwihyphenhyphenOJYJT1zxrGtTyNjTI8GK2PH14DmgaRLzvO1DbefVjPliM/s640/CALCULO+DE+CONDUCTOS.jpeg" width="426" /></a></div>
<div class="separator" style="clear: both; text-align: center;">
<br /></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal">
<br /></div>
<div class="MsoListParagraph" style="mso-list: l5 level1 lfo6; text-indent: -18.0pt;">
<!--[if !supportLists]-->5.<span style="font-size: 7pt;">
</span><!--[endif]-->Quinto, para pasar de diámetro a una sección
rectangular vamos al Abaco para conversión de conductos circulares en
rectangulares o cuadrados, elegimos una sección constante, ejemplo 30cm, porque
el entretecho no permite mas, y según el diámetro de cada conducto tendremos la
segunda sección que será variable</div>
<div class="MsoNormal">
<br />
<!--[endif]--></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjXxRGn4fDCgfLDNk0H2wfaQ4FGi7A_2HdpRzE2T36TG2DPRKPVZodPhlsEvGSZzvpNf36Lvd6K2sMNKCcfm6IuHf8twZbiIIRXQ8qWRqagw6SBuLdpi5xT28jjbsTHBIkjccJwP0VrcPY/s1600/CONVERSION+DE+CONDUCTOS+CIRCULARES+A+RECTANGULARES+EJEMPLO.JPG" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="400" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjXxRGn4fDCgfLDNk0H2wfaQ4FGi7A_2HdpRzE2T36TG2DPRKPVZodPhlsEvGSZzvpNf36Lvd6K2sMNKCcfm6IuHf8twZbiIIRXQ8qWRqagw6SBuLdpi5xT28jjbsTHBIkjccJwP0VrcPY/s400/CONVERSION+DE+CONDUCTOS+CIRCULARES+A+RECTANGULARES+EJEMPLO.JPG" width="303" /></a></div>
<div class="separator" style="clear: both; text-align: center;">
<br /></div>
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgsjPIO6uJEX-kwn-5ZdBXS5lagAoXk8uDWFu1NBhPGwtIY7OpTxS-oElsW90bbdcoT2FA7_S3iqPzE5LOxyhA4fvnKzUvfI-LelmhP69JXCxPvRdxmcBaeuIW6B4_8Jj3sLYTOMCKuNbs/s1600/CONVERSION+DE+CONDUCTOS+CIRCULARES+A+RECTANGULARES.jpeg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="640" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgsjPIO6uJEX-kwn-5ZdBXS5lagAoXk8uDWFu1NBhPGwtIY7OpTxS-oElsW90bbdcoT2FA7_S3iqPzE5LOxyhA4fvnKzUvfI-LelmhP69JXCxPvRdxmcBaeuIW6B4_8Jj3sLYTOMCKuNbs/s640/CONVERSION+DE+CONDUCTOS+CIRCULARES+A+RECTANGULARES.jpeg" width="442" /></a></div>
<div class="separator" style="clear: both; text-align: center;">
<br /></div>
<div class="MsoNormal">
<br />
<b><span style="text-transform: uppercase;">RELACION OPTIMA DE LOS CONDUCTOS DE AIRE</span></b><br />
Cuál es la relación de lados optima en un conducto de mando de aire acondicionado de sección rectangular?<br />
<div class="MsoNormal" style="margin-left: 18pt;">
La forma optima para un conducto de Aire es la circular d=a, le sigue la cuadrangular de lado a = lado b = a, y por último la rectangular de lado a=2 por lado b=4</div>
</div>
<div class="MsoNormal">
<br /></div>
<div class="MsoNormal" style="margin-left: 18.0pt; text-indent: 17.4pt;">
<b><span style="text-transform: uppercase;">CALCULO
DE LA CONTRAPRESION DEL VENTILADOR<o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l1 level1 lfo5; text-indent: -18.0pt;">
<!--[if !supportLists]-->1.<span style="font-size: 7pt;">
</span><!--[endif]-->Primero, establecer el caudal de aire:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l1 level2 lfo5; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Caudal de aire frio : C= Qsi / 170</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
Donde:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
Qsi: ganancia de calor sensible (Kcal / h)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
170: factor que surge de las diferencias de temperaturas entre el aire de
retorno y de alimentación, el peso y calor especifico del aire</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l1 level1 lfo5; text-indent: -18.0pt;">
<!--[if !supportLists]-->2.<span style="font-size: 7pt;">
</span><!--[endif]-->Segundo, se determina la contrapresión del
ventilador Hv, </div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l1 level2 lfo5; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Hv = (2 . ∑I . R) + (∑ Z)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l3 level2 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->∑I : sumatoria de la longitud mas
desfavorable o alejada incluyendo el retorno del circuito (m)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l3 level2 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->R: recta de maniobra, gradiente, obtenido por
abaco en el paso anterior (mmca/m)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l3 level2 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->∑ Z : sumatoria de los frotamientos
producidos por ( mmca):</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l3 level3 lfo4; text-indent: -9.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Rejas de alimentación y difusores: 2 mmca, mas</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l3 level3 lfo4; text-indent: -9.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Rejas de retorno : 1 mmca, mas</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l3 level3 lfo4; text-indent: -9.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Persianas fijas o regulables : 1.5 mmca, mas</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l3 level3 lfo4; text-indent: -9.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Plenos :
1 mmca, mas</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l3 level3 lfo4; text-indent: -9.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Filtros de aire comunes : 5 mmca, mas</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l3 level3 lfo4; text-indent: -9.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Baterías 1.5 a 2.5 mmca por hilera</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
Todos son datos del fabricante</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l3 level2 lfo4; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Hv : presión que debe establecer el ventilador
(mmca)</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l1 level1 lfo5; text-indent: -18.0pt;">
<!--[if !supportLists]-->3.<span style="font-size: 7pt;">
</span><!--[endif]-->Tercero, se verifica que Hv sea menor al HV
estipulado por el fabricante, </div>
<div class="MsoNormal" style="margin-left: 35.4pt;">
<br /></div>
<div class="MsoNormal" style="margin-left: 18.0pt;">
<b><span style="text-transform: uppercase;">CACULO DE LAS CAÑERIAS DE AGUA<o:p></o:p></span></b></div>
<div class="MsoListParagraphCxSpFirst" style="mso-list: l2 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]-->1.<span style="font-size: 7pt;">
</span><!--[endif]-->Primero, se determina el caudal de agua que
consume cada fan-coil:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Agua fría para refrigeración: C = Q/5.5</div>
<div class="MsoListParagraphCxSpMiddle">
Donde:</div>
<div class="MsoListParagraphCxSpMiddle">
C: caudal de agua fría (l/h)</div>
<div class="MsoListParagraphCxSpMiddle">
Q: ganancia de calor que debe extraer cada
fan-coil en el verano (Kcal/h)</div>
<div class="MsoListParagraphCxSpMiddle">
5.5 : la diferencia de temperatura entre el
agua de alimentación y retorno</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]-->2.<span style="font-size: 7pt;">
</span><!--[endif]-->Segundo, se determina la velocidad máxima
conveniente a la salida de la bomba:</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 53.4pt; mso-add-space: auto; mso-list: l0 level1 lfo1; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Para agua fría: 0.8 a 1.7 m/seg recomendada (1
m/seg)</div>
<div class="MsoListParagraphCxSpMiddle" style="mso-list: l2 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]-->3.<span style="font-size: 7pt;">
</span><!--[endif]-->Tercero, fijada la velocidad de descarga y con
el caudal máximo, que es la suma de todos los caudales que consumen cada
fan-coil del sistema, se va al abaco y se determina la recta de maniobra R.</div>
<div class="MsoListParagraphCxSpLast" style="mso-list: l2 level1 lfo2; text-indent: -18.0pt;">
<!--[if !supportLists]-->4.<span style="font-size: 7pt;">
</span><!--[endif]-->Cuarto, los diámetros de los segmentos que
requieren menos caudal se determinan trasportándose sobre esa recta constante R</div>
<div class="MsoNormal" style="margin-left: 18.0pt;">
<b><span style="text-transform: uppercase;">CALCULO
DE LA BOMBA CIRCULADORA</span></b></div>
<div class="MsoListParagraphCxSpFirst" style="margin-left: 39.3pt; mso-add-space: auto; mso-list: l4 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]-->1.<span style="font-size: 7pt;">
</span><!--[endif]-->Primero, se suman el caudal de todos los
fan-coil del sistema C (l/h)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 39.3pt; mso-add-space: auto; mso-list: l4 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]-->2.<span style="font-size: 7pt;">
</span><!--[endif]-->Segundo, se determina la presión eficaz de la
bomba Hb</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l4 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Hb = (2 . ∑I . R) + (∑
Z)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l4 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->∑I : sumatoria de la longitud mas
desfavorable o alejada incluyendo el retorno del circuito (m)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l4 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->R: gradiente hidráulico, obtenido por abaco en
el paso anterior (mmca/m)</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l4 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->∑ Z : sumatoria de los frotamientos
producidos por ( mmca):</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l4 level3 lfo3; text-indent: -9.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->La unidad enfriadora: 2.6 mca, mas</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 108.0pt; mso-add-space: auto; mso-list: l4 level3 lfo3; text-indent: -9.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Los fan-coil: 1.3 mca</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
Todos son datos del fabricante</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto; mso-list: l4 level2 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]--><span style="font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol;">·<span style="font-family: 'Times New Roman'; font-size: 7pt;">
</span></span><!--[endif]-->Hb : presión de la bomba en mca</div>
<div class="MsoListParagraphCxSpMiddle" style="margin-left: 72.0pt; mso-add-space: auto;">
<br /></div>
<div class="MsoListParagraphCxSpLast" style="margin-left: 39.3pt; mso-add-space: auto; mso-list: l4 level1 lfo3; text-indent: -18.0pt;">
<!--[if !supportLists]-->3.<span style="font-size: 7pt;">
</span><!--[endif]-->Tercero, con el caudal máximo o total C (l/h) y
la presión de la bomba Hb (mca) se obtiene la potencia de la bomba necesaria,
ya que son datos que suministra el fabricante</div>
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com1tag:blogger.com,1999:blog-3273325622788575209.post-6721537114122748312013-02-15T09:03:00.004-08:002013-02-15T09:03:49.382-08:00CAÑERIASCAÑERIAS<br />
Las cañerías que se utilizan generalmente son:<br />
• Metálicas: ferrosas de acero o no ferrosas de cobre o latón
o Cañerías de acero<br />
Hierro negro, ya en desuso<br />
Galvanizadas, ya en desuso
o Cañerías de latón<br />
hidrobronz, pueden ser del tipo reforzado o especiales de mayor espesor, provistas con extremos para roscar y también con aislación térmica de pvc, se unen por soldadura capilar<br />
• Plásticas: de polietileno reticulado o polipropileno simples o compuestos con aluminio
o Caños plásticos<br />
Polietileno reticulado, denominada PEX, su curvatura es sencilla pero no puede unirse con termofusión, se unen por piezas<br />
Polipropileno, permite la unión por termo fusión<br />
Tubos compuestos de aluminio, es un tubo de aluminio revestido con polietileno reticulado denominado Pex-Al-Pex, o PPR-al-PPR, puede unirse por termofusión
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-74998931367226453552013-02-15T09:02:00.000-08:002013-02-15T09:15:05.635-08:00AISLAMIENTO TÉRMICO DE CAÑERÍASAISLAMIENTO TÉRMICO DE CAÑERÍAS<br />
El aislamiento reduce las pérdidas de calor y evita las condensaciones del vapor de agua del aire sobre la superficie de los caños, cuando la temperatura está por debajo del punto de rocío.<br />
• En caños plásticos se usan<br />
o coberturas tubulares termo-aislantes de espuma de polietileno, que se insertan en el tubo y luego se completa la unión con cinta autoadhesiva y termo-aislante, evitando el ingreso de aire.<br />
o Lana de vidrio mineral o polietileno expandido en medias cañas que se unen con alambre.
En general se adoptan aislaciones de 25 mm de espesor al interior y 50 mm al exterior.
En todo aislamiento térmico es necesario colocar en su exterior una barrera vapor que evite la propagación del aire dentro del material aislante. Para ello se usa, revestimientos asfálticos, cintas plásticas, delgadas chapas de aluminio, etc.
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-91308198762627733542013-02-15T08:47:00.000-08:002013-02-15T08:47:10.120-08:00PRUEBA HIDRÁULICA DE ESTANQUEIDADPRUEBA HIDRÁULICA DE ESTANQUEIDAD<br />
Debe efectuarse pruebas parciales y una final de estanqueidad de toda la instalación, con una presión de 1.5 a 2 veces la de trabajo durante 24 hs mínimo.
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-46531439919866089362013-02-15T08:46:00.002-08:002013-02-15T08:46:21.987-08:00DESAGÜE DEL AGUA DE CONDENSADODESAGÜE DEL AGUA DE CONDENSADO<br />
La humedad extraída por condensación del aire interior, es recogida en una bandeja y esta es eliminada por a la instalación de desagüe primario del edificio, sifón, o pileta de piso mediante.
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0tag:blogger.com,1999:blog-3273325622788575209.post-18451726296862026862013-02-15T08:45:00.004-08:002013-02-15T08:45:40.050-08:00ELEMENTOS DEL CIRCUITO HIDRAULICOELEMENTOS DEL CIRCUITO HIDRÁULICO<br />
• Válvulas manuales<br />
o Válvulas esclusas<br />
o Válvulas globo<br />
o Válvulas a diafragma<br />
o Válvulas esféricas<br />
o Válvulas mariposa<br />
o Válvulas de retención<br />
• Filtros de agua, tiene la función de evitar la recirculación de impurezas tales como suciedades, óxidos, etc. Que puedan afectar a las bombas, válvulas, instrumentos de medición. Uno de los filtros más conocidos es llamado, filtro “Y” o canasto, provisto de una tapa de desmonte para su limpieza.<br />
• Vaso de expansión<br />
o Tanques de Expansión, pueden ser abiertos o cerrados, los abiertos están sometidos a presión atmosférica, se ubican al nivel superior de la instalación y cumple con la función de cargar agua a la instalación de agua fría, su volumen puede calcularse mediante:<br />
V = Q/500<br />
Donde:<br />
V: volumen del tanque (litros)<br />
Q: capacidad de la unidad enfriadora de agua (frig/h)<br />
• Válvulas de desaire, utilizadas para el purgado del aire en las cañerías, se ubican en los extremos superiores de la instalación, en los colectores, en unidades enfriadoras, etc. Pueden ser automáticas o manuales<br />
• Bombas circuladoras, se emplean para circular el agua, se montan sobre bases antivibratoria. En instalaciones grandes se utilizan dos en by-pass por si una falla o si hay que hacerle algún mantenimiento. Pueden instalarse en el circuito de alimentación como en el de retorno de agua fría.
ARQ. Fernando A. DIAZhttp://www.blogger.com/profile/11372484963508813241noreply@blogger.com0